Approval
Underwriter Laboratories (UL), UL508 and CSA C22.2 No. 142−M1987, (UL File Number
E236341)
Ratings
ƒ
Input 24 V DC, 65 W
ƒ
For use on an isolated power supply rated 24V DC 4A max.
ƒ
Max. ambient temperature 40°C
ƒ
Max. surrounding temperature 50 °C
ƒ
Optional communication ratings:
– RS232−Connection (APL and DPL version only): max. 3 A
– USB−Connection (DVI version only): max. 1 A
– PS/2−Connection: max. 1 A
– VGA−Connection (APL version only): max. 4 A
– FBAS−Connection (APL version only): max. 4 A
– DVI−Connector (DVI version only): max. 4 A
– DPL−Connection (DVI version only): max. 4 A
– External Power Supply for DVI/USB Extender: max. 4 A
– Video−DSUB Connection for DVI/USB Extender: max. 4 A
– Data−DSUB Connection for DVI/USB Extender: max. 4 A
ƒ
Environmental ratings: If these devices are mounted into a door or front cover of an
enclosure: Type 1 Enclosure.
O
Warnings!
Conditions of acceptability
ƒ
These devices are for Type 1 front panel mounting only.
ƒ
The external power supply connection is suitable for field wiring. An isolated
power supply rated 24 V DC, 4 A max. must be used.
Field Wiring Markings
Wiring Terminal MSTB 2,5/3−STF−5,08:
ƒ
Use Copper Wire only.
ƒ
AWG 18 ... AWG 12 (0.82 mm
2
... 3.3 mm
2
)
ƒ
Torque 5...7 lb−in (0.5 ... 0.6 Nm)