Mounting cutout, Mechanical installation, 2 mounting cutout – Lenze MP 9000 DVI Operating Instructions User Manual
Page 25: All dimensions in millimetres
![background image](/manuals/565648/25/background.png)
Mechanical installation
Mounting cutout
l
25
BA_MP9000DVI DE 4.0
5.2
Mounting cutout
0
1
a1
a2
£ 5
2
b
1
b
2
b
3
b
5
b
4
D
ELx7xx−004
0 Mounting cutout
1 Outline of front panel
2 Control board
All dimensions in millimetres.
Dimensions
a1
a2
b1
b2
b3
b4
b5
D
[mm]
MP 800 DVI
246
−
188
−
−
−
−
−
MP 1000 DVI
305.0
−
228.0
−
−
−
−
−
MP 1000s DVI
MP 1050 DVI
343.0
−
228.0
−
−
−
−
−
MP 1050s DVI
MP 2000 DVI
340.0
351.0
288.0
122.0
122.0
0.0
−
6 x
Æ5.5
MP 2050 DVI
375.0
386.0
288.0
122.0
122.0
0.0
−
MP 5000 DVI
400.0
411.0
313.0
134.5
134.5
0.0
−
MP 5020 DVI
452.0
462.4
299.0
104.9
104.6
15.7
−
MP 5050 DVI
MP 5070 DVI
452.0
462.4
388.2
149.3
149.3
15.9
−
MP 9000 DVI
438.0
451.0
386.0
172.0
172.0
60.0
60.0
8 x
Ж4.5
This manual is related to the following products: