Technical data, General data and operating conditions, 4technical data – Lenze MP 9000 DVI Operating Instructions User Manual
Page 20
Technical data
General data and operating conditions
4
l
20
BA_MP9000DVI DE 4.0
4
Technical data
4.1
General data and operating conditions
General data
Conformity and approval
Conformity
CE
EN 61000−6−4
EN 61000−6−2
EMC Directive Class A, industrial premises
Approbation
UR
UL 508
CSA C22.2
Programmable Controllers (File−No. E236341)
Other
RoHS
−
Products lead−free in accordance with CE Directive
2011/65/EU
Protection of persons and equipment
Safety
VDE0805 (EN60950),
VDE0870, UL
Enclosure
EN 60529
IP65 (front) / IP20 (back)
UL 508 (NEMA 250)
Type 1 enclosure
Class of protection
3
EMC
Noise emission
EN 61000−6−4
Class A (industrial premises)
Noise immunity zone B
EN 61000−6−2
Industrial premises
EN 61000−4−2
ESD; severity level 3, i. e.
8 kV for air discharge,
4 kV for contact discharge
EN 61000−4−3
RF interference (housing)
80 MHz
1000 MHz, 10 V/m 80 % AM (1 kHz)
EN 61000−4−4
Burst, severity level 3
EN 61000−4−5
Surge, severity level 1 *
EN 61000−4−6
RF cable−guided
150 kHz
80 MHz, 10 V/m 80 % AM (1 kHz)
*
Due to the high−energy single current pulses, surges require suitable external wiring with lightning protection
elements like for example lightning conductors and overvoltage arresters.