Power connection, Reservoir & pump connections – Koolance RP-980SL User Manual
Page 13

8
Power Connection
You may begin the installation of your Koolance system by mounting a power supply
in the chassis. With 3 radiator fans, the liquid cooling system requires approximately
26W (peak) from any standard ATX power supply.
Connect a 12 Volt 4-pin Molex plug from the power supply to the power connection
on the rear of the reservoir bay unit. Without this important connection, the cooling
system will NOT operate.
Connecting PC4-1000 Systems
Reservoir & Pump Connections
POWER
: Main
cooling connection
from power supply
FAN
: Radiator fan
connection, plus 1
optional plug
TEMP
: Temperature
sensors shown on
the Koolance LED
display
ATX
: Pass-through
lead for power shut-
down feature
IN/OUT
: Liquid
nozzle sockets
The radiator fans, temperature sensors, and ATX pass-through wire should already
be connected to your reservoir unit. If not, please connect them where indicated
below. Also insert your desired Koolance inlet and outlet G 1/4 threaded nozzles.