Koolance EX2-750SL User Manual
Page 26
21
User Manual
Allow the pumps to run for about 1-5 minutes. When fi ltration has ended, the
liquid noise should stop. If the reservoir level becomes signifi cantly lower
during this “bleeding” process, add more liquid coolant. (In the future, if
you begin to hear liquid rushing through the reservoir, it may indicate more
coolant needs to be added.)
Replace the refi ll plug screw.
The cooling system can be “jump-started” to assist in the
circulation process without booting-up the computer. This
will also allow you to check your hose connections and make
sure there are no folds in the tubing.
CAUTION
:
Jumping the incorrect ATX power supply pins can cause
permanent damage to the power supply.
!
Make sure the AC power cord is attached to the power supply. If the power supply
has a rear switch, it must be in the ON (-) position. Using the ATX Jumper Wire,
insert the metal prongs into the fourth and sixth connectors on the 20 pin moth-
erboard ATX power supply connector (usually green and a black ground wire; See
diagram).
That’s it! Replace the ATX motherboard connection and boot-up the computer.
CAUTION
:
When fi lling, the Exos must be
higher than all internal liquid coolers, or
coolant will exit the refi ll tap upon fi lling.
!
Because of gravity, the Exos must be placed above all internal
cooling components while being fi lled. Otherwise, coolant will
exit the refi ll tap once the reservoir is full.
4
6