Led display panel – Koolance EX2-750SL User Manual
Page 10
5
User Manual
LED Display Panel
Temperature Sensors
Exos-2 systems can monitor up to 3 temperature sensors (included). The fi rst
LED digit indicates which sensor channel is currently displayed in the temperature
reading. To cycle through sensors, press SET.
Fan Speed
This option adjusts the radiator fan speed. Higher speeds can improve performance,
but will produce more noise. There are 1 automatic and 10 manual fan settings
(1-10). Press the
▲ or ▼ buttons to cycle through these settings, or hold down
an arrow to skip to the highest or lowest mode directly.
Automatic mode will adjust the fans for you based on temperature values from
sensor #1. This mode is reached by lowering the fan setting to “0” (Aut / A1 will
be displayed). Details on fan modes are as follows:
CAUTION: Exos-2 systems allow full user control of hardware safety
settings, such as audio alarm and shutdown. Please be sure to con-
fi gure your LED Display Panel properly, or damage to your computer
and equipment could result.
!
Auto Mode
Manual Mode
Fan Power %
Total CFM
Fan RPM
0 - 35ºC (32 - 95ºF)
1
30
56
720
36 - 37ºC (97 - 99ºF)
2
35
66
840
38 - 39ºC (100 - 102ºF)
3
40
75
960
40 - 41ºC (104 - 106ºF)
4
45
85
1080
42 - 43ºC (108 - 109ºF)
5
50
94
1200
44 - 45ºC (111 - 113ºF)
6
60
113
1440
46 - 47ºC (115 - 117ºF)
7
70
132
1680
48 - 49ºC (118 - 120ºF)
8
80
150
1920
50 - 51ºC (122 - 124ºF)
9
90
169
2160
52 - 99ºC (126 - 210ºF)
10
100
188
2400
Sensor Channel
Temperature Value
Cycle Sensor Channels
Display in ºC or ºF
Increase Fan Speed
Decrease Fan
Speed