beautypg.com

Press, Ωv/a, English – Klein Tools CL3100 User Manual

Page 3: Symbols used on lcd, Electrical specifications

background image

ENGLISH

Continuity

V

AT

0

10

20

40

30

Apro

PRESS

V/A

400V

CATIII

400V

CATIII

correct

Incorrect:

Opposing currents cancel

2. current:

< 200a ac

Continuity

V

AT

0

10

20

40

30

Apro

resistance: < 40M

Ω

3.

resistance / continuity

continuity: tone below 30

Ω

SYMBoLS USED oN LcD

~

ac Measurement

Dc Measurement

-

Negative Dc Value

Low Battery

MAX

Maximum reading

MIN

Minimum reading

AT

auto range active

AUTO

auto Function

active (V/a)

O.L.

overload: range

Exceeded

Apo

auto Power-off active

V

Voltage Measurement

A

current in amps

Ω

resistance in ohms

continuity test

m

Milli 10

-3

k

Kilo 10

3

M

Mega 10

6

ELEctrIcaL SPEcIFIcatIoNS

Dc Voltage Measurement

range

resolution

accuracy

2.1 ~ 1000V

0.001V ~ 1V

± (1.0% + 4 digits)

-1.8 ~ -1000V

0.001V ~ 1V

overload Protection:

1000V

Input Impedance:

>

10M

Ω

ac Voltage Measurement

range

resolution

accuracy

1.3 ~ 750V

0.001V ~ 1V

± (1.5% + 3 digits)

overload Protection:

750V RMS

Frequency:

45 to 400Hz

Input Impedance:

10M

Ω

response:

Averaging

ac current Measurement

range

resolution

accuracy

0.9 ~ 200A

0.1A

± (2.5% + 8 digits)

overload Protection:

200A

Frequency:

45 to 400Hz

response:

Averaging

resistance Measurement

range

resolution

accuracy

400

Ω

0.1

Ω

± (1.0% + 4 digits)

4

0.001k

Ω

40

0.01k

Ω

400

0.1k

Ω

4

0.001M

Ω

40

0.01M

Ω

± (2.0% + 4 digits)

overload Protection:

600V

continuity test

overload Protection

open circuit Voltage

600V

Appx. 0.45V