Mm2000 instruction manual, English, General specifications – Klein Tools MM2000 User Manual
Page 2: Warnings, Symbols
ENGLISH
MM2000
Instruction Manual
GENERAL SPECIFICATIONS
The Klein Tools MM2000 is a True RMS, auto-ranging multimeter.
It measures AC / DC voltage, low impedance voltage, AC / DC current,
resistance, capacitance, frequency, duty cycle, and temperature.
It can also test diodes and continuity.
•
Operating Altitude:
2000 m
•
Relative Humidity:
< 75%
•
Operating Temperature:
0°C / 32°F to 40°C / 104°F
•
Storage Temperature:
-20°C / -4°F to 60°C / 140°F < 80% R.H.
•
Accuracy Temperature:
18°C / 64°F to 28°C / 82°F
•
Temperature Coeffi cient:
0.1*(specifi ed accuracy) / °C
•
Sampling Frequency
: 3 samples per second
•
Dimensions:
7" x 3.5" x 1.875"
•
Weight:
14 oz.
•
Calibration
: Accurate for one year
•
CAT Rating:
CAT III 1000V, CAT IV 600V
•
Accuracy:
± (% of reading + # of least signifi cant digits)
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use, verify meter operation by measuring
a known voltage or current.
• Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
• Do not use the meter during electrical storms, or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Ensure meter leads are fully seated, and keep fi ngers away from
the metal probe contacts when making measurements.
• Do not open the meter to replace batteries while the probes
are connected.
• Use caution when working with voltages above 60V DC,
or 25V AC RMS. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock,
replace batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lock out
power before measuring resistance or capacitance.
• Always adhere to local and national safety codes. Use individual
protective equipment to prevent shock and arc blast injury where
hazardous live conductors are exposed.
SYMBOLS
~
AC Alternating Current
Warning or Caution
DC Direct Current
Double Insulated Class II
DC/AC Voltage or Current
AC Source
Ground