Product Over view
K
D
S
L
e
g
a
to
1
0
0
S
e
ri
e
s
U
s
e
r’s
M
a
n
u
a
l
KD Scientific Legato 100 Series Syringe Pump User’s Manual
Publication 5617-006 Rev D
Easy external connections to a computer or other control
devices are made through USB interface. Simple ASCII
commands make communication with the pump easy. For
direct control of the pump, the user can use the I/O
interface (15pin Dsub). A trigger output and a trigger
input in for external events such as a process parameter is
met. The footswitch input will allow the control of the
pump through an external device. The unit also has an
output for run indication allowing connection to a remote
light.
Single or dual syringes models are available. Complete
flexibility is offered with the user able to use most
manufacturer’s syringes with sizes ranging from 0.5 ul to
60 ml.
The infuse/withdraw programmable models Legato (110,
111 and 180) offer maximum flexibility and capability for
configuring and running different programs. Up to 2
programs of 50 steps each can be configured and stored
in the unit, and recalled quickly with the touch of a
button. The programs are identified with a 15 character
alphanumeric name for easy identification and can be
stored on the computer and downloaded at future dates.
A relative clock is available to start and stop programs
based on time. Extensive programming options allow the
user to duplicate configurations, append one
configuration to another, rename programs, delete
programs, export programs to a PC or export a program
to another pump. This feature can ensure consistency and
accuracy of multiple pumps.
Preprogrammed profiles include Constant Rate and
Ramp. These standard profiles make configuration easy
to set up. If more complexity is needed the user can select
from advanced programming options including:
•
Time delays
•
Repeating steps
•
Stopping the pump
•
Triggering the pumps TTL output
•
Accepting an event input in such as a user
touch
•
Events can trigger the pump to withdraw or infuse
The pump Information/setup screen shows the pump’s
software version, and lubrication intervals. The pump’s
alarm configurability includes alarms for near end of run
(user selectable), completion of run, power up, keypad
clicks and stall detection.
Pump Models
The Legato 100 Series is available in 5 different
configurations.
Legato 100
– Single syringe infuse only.
Legato 110
– Single syringe infuse/withdraw with
program option for 2 programs, 50 steps each..
Legato 101
– Dual syringe infuse only. Syringe size
0.5 µl to 10 ml.
Legato 111
– Dual syringe infuse/withdraw with program
option for 2 programs, 50 steps each.
Legato 180
– Dual syringe infuse/withdraw optimized for
low flow with program option for 2 programs, 50 steps
each. Syringe size 0.5 µl to 10 ml.
phone
508.429.6809
fax
508.893.0160