2012-09-28/00536576

Data Sheet 902940

Page 3/17

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone: 315-697-5866

1-800-554-JUMO

Fax:

315-697-5867

E-mail:

[email protected]

Internet: www.jumousa.com

Ambient conditions

Accuracy of entire device

Load check, current
• Pulse period

2 s; T

ON

40 ms

• Periodic protection circuit

for overcurrent

f = 0.5 Hz
LCD display: Err3 switching output K1, Err4 switching output K2

Scaling range
Analog output

Scaling can be freely selected within the measuring range

Behavior when leaving the scaling
area (underrange)

Analog output 0 to 20 mA, linear drop up to 0 mA
Analog output 4 to 20 mA, linear drop up to 3.8 mA
Analog output 0 to 10 V, linear drop up to 0 V

Behavior when leaving the scaling
area (overrange)

Analog output 0 to 20 mA, linear increase up to 20.5 mA
Analog output 4 to 20 mA, linear increase up to 20.5 mA
Analog output 0 to 10 V, linear increase up to 10.2 V

Switching output
• Switching point

Measuring range (

>

release point)

• Release point

Measuring range (

<

switching point)

• Attenuation

0.00 to 99.99 s

• Switch-on delay

0.00 to 99.99 s

Burden
4 to 20 mA

R

I

(U

B

- 6.5 V) / 0.022 A

0 to 20 mA

R

I

(U

B

- 6.5 V) / 0.022 A

0 to 10 V

R

10 k

Ω

Admissible temperatures
Ambient temperature, display case

-25 to +75 °C

Ambient temperature

-50 °C; restricted function
only stationary use, risk of cable break, LCD display without function

Storage temperature

-40 to +85 °C

Admissible air humidity
• During operation

100 % including condensation on the device outer case

• In storage

90 % without condensation

Admissible mechanical load

Referring to basic type 902940/10 and 902940/30 with insertion length 100 mm

• Vibration resistance

10 g, 10 to 2000 Hz according to IEC 60068-2-6

• Shock resistance

50 g for 11 ms / 100 g for 1 ms according to IEC 60068-2-27

Electromagnetic compatibility

(Only with 4-pin connecting cable and grounded case)

• Interference emission

Class A according to EN EN 61326

• Interference immunity

Performance characteristic A according to EN 61326

Protection type

IP67 according to DIN EN 60529

Ambient temperature influence

≤ ±

(15 ppm/K × (measuring range end value + 200) + 50 ppm/K × configured measuring range) ×

Δϑ

Δϑ

= deviation of the ambient temperature from the reference temperature

Calibration/reference conditions

DC 24 V at 25 °C

±

5 °C (77 °F

±

9 °F)

Measured value

Tolerance

100 °C

0.60 K

150 °C

0.75 K

200 °C

1.00 K

450 °C