beautypg.com

JUMO 60.3035 Surface-mounting single or twin thermostat, ATH-SW Data Sheet User Manual

Page 4

background image

2013-03-12/00376440

Data Sheet 603035

Page 4/9

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

Ambient temperature influ-
ence referring to the control /

limit value range

When the ambient temperature on the case deviates from the calibration ambient temperature 22 °C,

a switch point offset occurs.

Higher ambient temperatures = lower switching point

Lower ambient temperature = higher switching point

Add-on thermostats with scale limit value

< 200 °C

≥ 200 °C ≤ 350 °C

> 350 °C ≤ 500 °C

TW

STB/STW (STB)

TW

STB/STW (STB)

TW

STB/STW (STB)

Influence on the switch head

0.08%/K

0.17%/K

0.06%/K

0.13%/K

0.14%/K

0.12%/K

Influence on the capillary per metre

0.047%/K

0.054%/K

0.09%/K

0.11%/K

0.04%/K

0.03%/K

admissible ambient tempera-
ture for use

max. +80 °C

admissible storage tempera-
ture

-50 to +50 °C

Rated position

any

Case

standard

Aluminum die casting, painted

Set point adjustment

The switching point can be adjusted by means of a screwdriver once the case lid has been removed

Protection class

EN 60 529-IP 65

Cable inlet

Cable screw connection M 20 x 1.5, sealing area 6-12 mm

Switch head is fastened
Type series ATHf-SW
with capillary

with 2 screws through the case bottom part (wall mounting),

lateral capillary outlet in the case.

Weight

approx. 1.2 kg

Process connection

a

a

For different process connections and sheaths, refer to data sheet 606710.

Type series ATHs-SW
with rigid shaft

Scale limit value up to 150 °C

sheath "20“

Scale limit value over 150 °C

sheath "30“

Screw-in sleeve with screw-in spigot G 1/2

form A as per DIN 3852/2

Screw-in sleeve with screw-in journal G 1/2

form A as per DIN 3852/2 and intermediate piece,

to ensure that the max. admissible ambient tempera-

ture of +80 °C is not exceeded on the case

Type series ATHf-SW
with capillary

plain cylindrical probe "10“ as standard

Screw-in sheath "20“ on request

Screw-in sleeve with screw-in spigot G 1/2 form A as per DIN 3852/2

and clamping piece with locking screw to lock the probe

Material

Sheath "20“

Sheath "30“

up to +150 °C CuZn as a standard

over +150 °C CrNi

over +150 °C CrNi

Fitting length S

Standard lengths: 100, 120, 150, 200 or 300 mm

different lengths on request

Immersion tube

Single thermostat D = 8 mm

Double thermostat D = 15 mm