Ambient temperature influ-
ence referring to the control /
limit value range
When the ambient temperature on the case deviates from the calibration ambient temperature 22 °C,
a switch point offset occurs.
Higher ambient temperatures = lower switching point
Lower ambient temperature = higher switching point
Add-on thermostats with scale limit value
< 200 °C
≥ 200 °C ≤ 350 °C
> 350 °C ≤ 500 °C
TW
STB/STW (STB)
TW
STB/STW (STB)
TW
STB/STW (STB)
Influence on the switch head
0.08%/K
0.17%/K
0.06%/K
0.13%/K
0.14%/K
0.12%/K
Influence on the capillary per metre
0.047%/K
0.054%/K
0.09%/K
0.11%/K
0.04%/K
0.03%/K
admissible ambient tempera-
ture for use
max. +80 °C
admissible storage tempera-
ture
-50 to +50 °C
Rated position
any
Case
standard
Aluminum die casting, painted
Set point adjustment
The switching point can be adjusted by means of a screwdriver once the case lid has been removed
Protection class
EN 60 529-IP 65
Cable inlet
Cable screw connection M 20 x 1.5, sealing area 6-12 mm
Switch head is fastened
Type series ATHf-SW
with capillary
with 2 screws through the case bottom part (wall mounting),
lateral capillary outlet in the case.
Weight
approx. 1.2 kg
Process connection
a
a
For different process connections and sheaths, refer to data sheet 606710.
Type series ATHs-SW
with rigid shaft
Scale limit value up to 150 °C
sheath "20“
Scale limit value over 150 °C
sheath "30“
Screw-in sleeve with screw-in spigot G 1/2
form A as per DIN 3852/2
Screw-in sleeve with screw-in journal G 1/2
form A as per DIN 3852/2 and intermediate piece,
to ensure that the max. admissible ambient tempera-
ture of +80 °C is not exceeded on the case
Type series ATHf-SW
with capillary
plain cylindrical probe "10“ as standard
Screw-in sheath "20“ on request
Screw-in sleeve with screw-in spigot G 1/2 form A as per DIN 3852/2
and clamping piece with locking screw to lock the probe
Material
Sheath "20“
Sheath "30“
up to +150 °C CuZn as a standard
over +150 °C CrNi
over +150 °C CrNi
Fitting length S
Standard lengths: 100, 120, 150, 200 or 300 mm
different lengths on request
Immersion tube
∅
Single thermostat D = 8 mm
Double thermostat D = 15 mm