Technical data, Switching function – JUMO 60.3035 Surface-mounting single or twin thermostat, ATH-SW Data Sheet User Manual

Page 2

background image

2013-03-12/00376440

Data Sheet 603035

Page 2/9

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

Technical Data

Switching function

Temperature monitor TW

Restart lock for the safety man-
ual reset temperature limiter
STB

Use of the safety
tem-perature monitor
STW as safety tem-
perature limiter STB

Self-monitoring for the safety temperature
limiter STB and safety temperature monitor
STW (STB)

If the temperature exceeds the
setpoint value set on the tempera-
ture probe, the microswitch will
be tripped by the transmission
mechanics and the current circuit
opened or closed.

The microswitch is reset to its
original status once the set point
value set is gone below (by the
hysteresis).

If the temperature exceeds the
limit value set on the temperature
probe, the current circuit is
opened and the microswitch
mechanically locked.

The microswitch can be manually
unlocked, once the dangerous
temperature is gone below by
approx. 10 % of the scale range
(approx. 15 % with a limit value
setting

> 350 °C).

Ensure that the
switching circuit
downstream of the
thermostat complies
to DIN EN 14597 and
VDE 0116.

If the measuring system is destroyed, i.e. if
the expansion fluid escapes, the pressure in
the diaphragm of the STB and STW drops and
permanently opens the current circuit.
Unlocking is no longer possible.

If the probe has cooled down to a tempera-
ture within the control range table, e.g. below
-20 °C, the current circuit is also opened. If
the temperature rises above -20 °C, the STB
must be unlocked manually. The STW auto-
matically restarts.

Control ranges and temperature probes

fluid-filled

Switching function

Control and limit

value ranges

in °C

maximum

admissible probe

temperature

in °C

maximum

capillary length

mm

Probe length, dimension "L" in mm

Probe

"d“ = 6 mm (standard)

TW

-20 ... +50

-10 ... +40

0 ... +50

0 ... +70

+0 ... +100

+20 ... +090

+30 ... +110

+20 ... +120

+60 ... +130

+20 ... +150

+50 ... +200

+50 ... +250

+50 ... +300

060

050

060

080

125

115

135

140

150

175

230

290

345

5000

141

185

185

138

107

138

125

106

135

88

101

73

63

STW and STB

+30 ... +110

+60 ... +130

+20 ... +150

+50 ... +250

+50 ... +300

135

150

175

290

345

5000

108

116

077

064

055

gas-filled

TW

+20 ... +400

+20 ... +500

+20 ... +500

460

575

575

1000

2000

4000

278

148

202

STW and STB

+20 ... +400

+20 ... +500

+20 ... +500

460

575

575

1000

2000

4000

176

127

202