2 Instrument identification

8

2.2

Type designation

ATH-EXx-. .- .

ATH

Surface-mounting thermostat (with capillary)

ATH-

EXx

Marking for explosion-protected version

ATH-EXx-

. .

- .

Code number for the function:

2 =

0

Temperature monitor (TW)
with changeover contact.
Limit adjustable within the housing.

7 =

0

Temperature limiter (TB)
with changeover contact and restart lock-out.
Limit adjustable within the housing.

7-F =

0

Temperature limiter (TB)
with changeover contact and restart lock-out.
Limit is factory-set.

20 =

0

Fail-safe temperature monitor (STW)
with changeover contact.
Limit adjustable within the housing.

70 =

0

Break-proof protection temperature limiter (STB)
with change-over contact and restart inhibit.
The limit value can be set by the installing engineer–
before commissioning the plant – within the housing.

70-F =

0

Break-proof protection temperature limiter (STB)
with change-over contact and restart inhibit.
Limit value set to a fixed value at the factory.

ATH-EXx-. .-

.

F =

0

Designation for factory-set limit setting.

Extra code (TZ) 679:

Min. operating temperature: -50°C