Operating procedures, Power connection, Switching on / start - stop – JULABO SC 10000w Eco-Series Recirculating Coolers User Manual
Page 25

Recirculating Cooler
25
6. Operating
procedures
6.1. Power
connection
Caution:
 Only connect the unit to a power socket with an earthing contact (PE – protective
earth)!
 The power supply plug serves as a safe disconnecting device from the line and
must always be easily accessible.
 Never operate the unit with a damaged mains power cable.
 Regularly check the mains power cables for damage. 
 We disclaim all liability for damage caused by incorrect line voltages! 
 
 
 
Make sure that the line voltage and frequency match the supply voltage 
specified on the type plate. 
Deviations of ±10 % are permissible. 
 
 
6.2. Switching on / Start - Stop
9 5 X X 
X X X 
X X 
P X H X 
Version
 
 
Switching on:
 Turn on the mains power switch (1).
The unit performs a self-test. All segments of the 4-digit MULTI-
DISPLAY (LED) and all indicator lights will illuminate. 
Then the order nomber (Example: [ 9501 ] [ 051] [ 03 ] [ P0H1 ]) and 
the software version (example: n3.1) of the unit appears. 
 
The display „OFF“ or „R OFF“ indicates the unit is ready to operate. 
 
 
The recirculating cooler enters the operating mode activated before 
switching the circulator off: 
keypad control mode 
(manual operation, factory setting)
or 
remote control mode 
(operation via personal computer).
Start:
Press the start/stop key.
.
The MULTI-DISPLAY (LED) indicates the actual bath temperature. 
The circulating pump starts with a slight delay. 
 
Stop:
Press the start/stop key.
.
The MULTI-DISPLAY (LED) indicates the message "OFF". 
 