Johnson Systems CD-3000 Series Retrofit Control System User Manual
Page 31
31
K>XXXXXX
A pointer (>) appears to indicate hard-key modification is activated.
K>XXXXXX
Press MENU (
) to modify the first hard-key character.
K:>XXXXX
Press EXECUTE to advance to the second hard-key character.
K:>XXXXX
Press MENU (
) to modify the second hard-key character.
K:X>XXXX
Press EXECUTE to advance to the third hard-key character.
K:X>XXXX
Press MENU (
) to modify the third hard-key character.
K:XX>XXX
Press EXECUTE to advance to the fourth hard-key character.
K:XX>XXX
Press MENU (
) to modify the fourth hard-key character.
K:XXX>XX
Press EXECUTE to advance to the fifth hard-key character.
K:XXX>XX
Press MENU (
) to modify the fifth hard-key character.
K:XXXX>X
Press EXECUTE to advance to the sixth hard-key character.
K:XXXX>X
Press MENU (
) to modify the sixth hard-key character.
Press ESCAPE to exit the menu and save the desired hard-key code.
Press RESET to exit the menu without saving.
The menu will automatically timeout after 5 minutes of inactivity and save.
NOTE: Be sure to record and file the hard-key code on page 35 for future reference.
40. SERIAL#
View the microcontroller’s unique six-character silicone serial number.
XXXXXX
Shows the unique six-character serial number.
41. VERSION
View the microcontroller’s software version.
VER X.X
Shows the microcontroller’s software version.
42. EEPROM
View the type of EEPROM memory module plugged in.
All CD-3000 Series retrofit control systems come with a removable EEPROM memory
module located on the MADD-96 board in the control module. The EEPROM memory
module inserts into the PORT4 connector located on the upper left-hand side of the
board, and may be removed for safe storage.
The EEPROM type is programmed for parameter (P) or firmware (F) operation. A
parameter EEPROM is used to backup all of the current configuration settings. A
firmware EEPROM is used to update the current firmware version running on the
MADD-96 microcontroller to the firmware version saved on the EEPROM.
The EEPROM memory module supplied with all CD-3000 Series retrofit systems is
a parameter type with all of the factory default configuration settings saved onto it
before shipping.
MADD96-P
Indicates the EEPROM memory module is for a MADD-96 microcontroller.
MADD96-P
Indicates the EEPROM type is programmed for parameter (P) operation.
XXXXXX
Press EXECUTE to display the silicone serial number parameter.
DISABLED
Press EXECUTE and menu feature is disabled for factory use only.
MADD96-F
Indicates the EEPROM type is programmed for firmware (F) operation.
VER X.X
Press EXECUTE to display the version (VER) of the firmware.
DISABLED
Press EXECUTE and menu feature is disabled for factory use only.
NONE!
Indicates the EEPROM memory module is not installed.
43. FW-LOAD
Load new firmware into the MADD-96 via the EEPROM memory module.
If a firmware update is required, Johnson Systems Inc. may supply an EEPROM
memory module with the latest firmware version. The firmware EEPROM memory
module can be inserted into PORT4 on the MADD-96 board and the firmware can be
loaded into the microcontroller.
Press EXECUTE to enter the menu.
DISABLED
This menu is disabled for inadvertent use. Proceed to enable.
ENABLED
Press and hold MENU (
) and MENU (
) at the same time for 4-5 seconds.
MEMCHECK
Automatically checks the EEPROM memory module for firmware type.