Johnson Systems CD-3000 Series Retrofit Control System User Manual
Page 28
28
26. OC MODE
Configure the input trigger parameters for the open collector output.
The on-board open collector output is used to sink up to 100mA of current. It can be
configured to be triggered via a selected DMX channel, analog input 4, or both. The
open collector is triggered on at 55% control input and triggered off again at 45%
control input. When analog and DMX (A+D) is selected to trigger the open collector
the inputs are combine for highest takes precedence (HTP).
Press EXECUTE to enter the menu and configure the open collector output.
A+D< 001
Displays the active trigger mode as analog and DMX (A+D<) channel 001.
A+D> 001
Press EXECUTE to toggle the pointer (>) and select the DMX channel.
A+D> 512
Press MENU (
) to change and select the DMX channel from 001 to 512.
A+D< 512
Press EXECUTE to toggle the pointer (<) and select a different trigger mode.
DMX< 512
Press MENU (
) to select DMX input trigger mode.
ANA<
Press MENU (
) to select analog (ANA) input trigger mode.
OFF<
Press MENU (
) to deactivate (OFF) the open collector output.
Press ESCAPE to exit the menu and save the desired settings.
Press RESET to exit the menu without saving.
The menu will automatically timeout after 5 minutes of inactivity and save.
27. AUX IN
Select which scene the auxiliary input will trigger/enable.
When a contact is sensed on the auxiliary input the selected scene will be triggered
and held until the contact is removed. The auxiliary input only functions when scene
mode (SCENESET) is activated or when the systems scene mode (SCENEMOD) is
enabled and active.
SCENE:01
Displays the scene (01) that will be triggered by the auxiliary input.
SCENE>01
Press EXECUTE to enter the menu and select a different scene.
SCENE>20
Press MENU (
) to change the selected scene from 01 to 20.
Press ESCAPE to exit the menu and save the desired scene to be triggered.
Press RESET to exit the menu without saving.
The menu will automatically timeout after 5 minutes of inactivity and save.
28. SCENEMOD
Enable or disable scene mode and the auxiliary input.
Enabling scene mode puts the system in scene mode. With scene mode enabled
the selected scene will always be activated when DMX is not being received. The
selected scene can be changed in the SCENESET menu. Scene mode enables the
use of the auxiliary input. A contact closure sensed on the over-temperature, fire
alarm or security alarm inputs automatically takes precedence over scene mode.
ENABLED
Press EXECUTE to toggle scene mode from ENABLED to DISABLED.
DISABLED
Press EXECUTE to toggle scene mode from DISABLED to ENABLED.
Any change in the configuration is automatically saved.
29. S-ALARM
Select the level and control channels triggered by the security alarm input.
When a contact is sensed on the security alarm input, the selected control channels
will cycle on and off at a 1 hertz rate. The level of the on cycle can be set from 0% to
100%. The security alarm input takes precedence over the DMX and analog inputs.
The system will stay in security alarm mode until the contact is removed.
Press EXECUTE to enter the menu and configure the security alarm input.
L>FL:01*
Displays the output level (L>FL) of 100% and control channel (01*).
L>00:01*
Press MENU (
) to change the output level from 00% to 100% (FL).
L>FL:01*
Press MENU (
) at the same time to toggle the level back to 100% (FL).
L:FL>01*
Press EXECUTE to toggle the pointer (>) and select the control channel(s).
L:FL>96*
Press MENU (
) to select the desired control channel from 01 to 96.
L:FL>96
Press EXECUTE to toggle the flag (*) for each desired control channel.
Press ESCAPE to exit the menu and save the desired settings.
Press RESET to exit the menu without saving.
The menu will automatically timeout after 5 minutes of inactivity and save.