Installation instructions, Shelf mounting instructions, Rack mounting instructions – Intelix FLX-8X8A User Manual
Page 11: General i/o card installation
FLX-8X8A Installation Guide
11
Installation Instructions
Shelf Mounting Instructions
Attach the supplied rubber feet to the bottom of the FLX-8X8A matrix. Follow the instructions in General
I/O Card Installation to install the I/O cards.
Rack Mounting Instructions
The FLX-8X8A requires two rack units (2 RU) of space.
At least 2 inches of free air space is required on
both sides of the FLX-8X8A for proper side ventilation. Avoid mounting the FLX-8X8A near a power
amplifier or any other source of significant heat. It is recommended that you leave an empty rack space
above and below the FLX-8X8A for additional cooling.
General I/O Card Installation
1. Power off the matrix.
2. Remove the metal blank.
3. Slide the I/O card between the guide rails until it is firmly seated.