Appendix – INFICON SQC-122C Thin Film Deposition Controller Operating Manual User Manual
Page 60

Appendix
Display
Graphs
Rate, Deviation, Power
Readouts
Thickness, Rate, Power
Process Parameters (a Process is a sequence of layers)
# Processes
25
# Films
25
# Layers (total all processes)
250
Layer Parameters (Layer is a Film, plus these values)
Initial Rate
0.0 to 999.9
?/sec.
Final Thickness
0.0 to 999.9
?
Time Setpoint
0 to 30000 sec.
Thickness Limit
0.0 to 999.9
?
Start Mode
Auto/Manual
# Rate Ramps
2
Rate Ramp Start
0.0 to 999.9
?
Rate Ramp Time
0 to 1000 sec.
New Rate
0.0 to 999.9
?/sec.
Film Parameters (Film is a Material, plus these values)
Material
100 stored
Density
0.40 to 99.99 gm/cm
3
Z-Factor
0.100 to 9.900
P Term
1 to 9999
I Term
0 to 99.9 sec.
D Term
0 to 99.9 sec.
Sensor (1,2)
On/Off
Output
1 or 2
1 to 8
Max Power
0.0 to 100.0 %
Slew Rate
0.0 to 100.0 %/sec.
Crystal Quality
Disabled to 30%
Crystal Stability
Disabled to 5000 Hz
Crystal Fail Mode
Halt or Timed Power
Ramp1, Ramp2, Feed Ramp, Feed, Idle Ramp Time
0 to 30000 sec.
Soak1, Soak2, Feed, Idle Power
0.0 to 100.0 %
Shutter Delay Time
0 to 200 sec.
Shutter Delay Error
0.0 to 30.0 %
Control Error
Ignore/Stop/Hold
Control Error Setting
0 to 30.0 %
Rate Sampling
Continuous/Time/Accuracy
Sample Time
10.0 to 999.0 sec.
Hold Time
10.0 to 999.0 sec.