INFICON I/O1000 I/O module User Manual
Page 11
![background image](/manuals/562406/11/background.png)
Description
11
5 - PLC OUT
Digital outputs
Electrical insulation (max. 60 V DC, 25 V AC against GND)
Max. permissible load per output: U = 30 V, I = 0.75 A
Fuses for digital outputs 1 ... 4 and 5 ... 8: 2 x 0.75 A
Connection plug arrangement
The digital outputs can be freely configured.
► For other layouts, see installation manual for mass spectrometer module
LDS3000.
Fig: 4
Digital outputs
Pin
Name
Factory setting mass spectrometer module
1
PLC-OUT 1
TRIGGER1 INVERTED
2
PLC-OUT 2
TRIGGER2 INVERTED
3
PLC-OUT 3
TRIGGER3 INVERTED
4
PLC-OUT 4
TRIGGER4 INVERTED
5
PLC-OUT 5
READY
6
PLC-OUT 6
ERROR INVERTED
7
PLC-OUT 7
CAL-REQUEST INVERTED
8
PLC-OUT 8
OPEN
9
PLC-OUT-COM
-
PLC_OUT_8
PLC_OUT_7
PLC_OUT_6
PLC_OUT_5
PLC_OUT_4
PLC_OUT_3
PLC_OUT_2
PLC_OUT_1
PLC_OUT_COM
FOA75
FOA75
8
7
6
5
4
3
2
1
0
See also other documents in the category INFICON Equipment:
- TGF10 Tracer Gas Filler (36 pages)
- Sensistor ILS500 F Leak Detection Filler (90 pages)
- T-Guard Leak Detection Sensor (85 pages)
- T-Guard Leak Detection Sensor Interface description (40 pages)
- Sensistor ISH2000P Hydrogen Leak Detector, Panel Model (51 pages)
- Sensistor ISH2000 HySpeed Hydrogen Leak Detector (54 pages)
- LDS3000 Modular Leak Detector (52 pages)
- LDS3000 Modular Leak Detector Interface description (56 pages)
- BM1000 Bus module (14 pages)
- CU1000 Control unit (24 pages)
- Helium Leak Detector Modul1000 (130 pages)
- Helium Leak Detector Modul1000 Interface description (40 pages)
- UL5000 Dry Helium Leak Detector (108 pages)
- UL5000 Dry Helium Leak Detector Interface description (14 pages)
- UL1000 Fab Dry Helium Leak Detector (119 pages)
- HLD6000 Refrigerant Leak Detector (76 pages)
- HLD6000 Refrigerant Leak Detector Interface Description (40 pages)
- IO1000 I/O module (18 pages)
- Ecotec E3000 Multigas-Sniffer-Leak Detector (92 pages)
- Ecotec E3000 Multigas-Sniffer-Leak Detector Interface description (36 pages)
- Sensistor XRS9012 Hydrogen Leak Detector User Manual (28 pages)
- Sensistor XRS9012 Hydrogen Leak Detector Maintenance manual (14 pages)
- Extrima Ex-certified Hydrogen Leak Detector (62 pages)
- Sensistor ILS500 Leak Detection System (107 pages)
- Sensistor ISH2000 Hydrogen Leak Detector (58 pages)
- Sensistor ISH2000 Hydrogen Leak Detector (108 pages)
- Sensistor Sentrac Hydrogen Leak Detector (86 pages)
- Protec P3000(XL) Helium Leak Detector (132 pages)
- Pilot Plus Vacuum Gauge (2 pages)
- CO Check Carbon Monoxide Meter (2 pages)
- GAS-Mate Combustible Gas Leak Detector (12 pages)
- Whisper Ultrasonic Leak Detector (8 pages)
- Vortex AC Refrigerant Recovery Machine 115V (20 pages)
- Vortex AC Refrigerant Recovery Machine 230V (16 pages)
- Wey-TEK Refrigerant Charging Scale & Optional Charging Module (2 pages)
- Wey-TEK Refrigerant Charging Scale & Optional Charging Module (44 pages)
- D-TEK CO2 Refrigerant Leak Detector (12 pages)
- TEK-Mate Refrigerant Leak Detector (12 pages)
- Compass Refrigerant Leak Detector (12 pages)
- D-TEK Select Refrigerant Leak Detector (12 pages)
- Explorer Portable Gas Chromatograph (369 pages)
- MicroFID II Portable Flame Ionization Detector (89 pages)
- DataFID Portable Flame Ionization Detector for Landfill Emissions Monitoring (91 pages)
- Hydrostik Hydrogen Fuel Cylinder Installation (7 pages)