INCRA CLEANSWEEP DOWNDRAFT DUST COLLECTION CABINET OWNER’S MANUAL
Fig. 7
Install Back Plate
4ea. 10-32
Hex Nut
(Captured in
hex feature)
Back Plate
4ea. 10-32 x 5/8”
Phillips Machine
Screw
Router is Sitting on Table Top
Router Cord
4 ea. #10
Lock Washer
ATTACH BACK PLATE
6. Bring your router or router lift assembly to the table
and set it adjacent to the opening in your table top.
Lower the electrical cord through the top of the table
and out the back of the CleanSweep cabinet. Slide the
cord into the cutout in the back plate as shown in
Fig. 7 then attach the back plate to the CleanSweep
using the (4) #10-32 x 5/8” Phillips machine screws
with lock washers and hex nuts as shown. The included
#10-32 x 5/8” hex head fasteners can be substituted for
the uppermost Phillips screws if your router table stand
aprons prevent access. Tighten all fasteners.
If you plan to also use your router table router as a hand held router from time to time, you might want to insert
a short extension cord into the strain relief bushing with the female plug just inside the CleanSweep Cabinet.
This will allow you to unplug and remove your router without also having to remove the back plate.
TIP
Fig. 8
Install Cord Strain Relief Bushing
Crimp strain
relief bushing on
cord and insert
into hole on
bottom of back
plate
Strain Relief Bushing
Fig. 9
Install Dust Hose
4” Dust Hose
(not supplied)
4” Hose Clamp
(supplied)
7. Add the strain relief bushing to the cord about 2’
from the router motor. Use a pair of pliers to squeeze
the 2 halves of the strain relief bushing together on the
cord and hold as you insert the cord and bushing into
the cutout on the back plate,
Fig. 8.
8. Use the included 4” hose clamp to attach your 4”
hose to the bottom of the CleanSweep,
Fig. 9.