Tam b, Bogen – Bogen PCM2000 User Manual
Page 14

CONFIGURATION 6:
EXTENDED PAGING SYSTEM
This illustration shows the wiring between a master assembly and a satellite assembly in a PCM system with a satellite assembly for one-way paging.
As described previously, the required setup for one-way basic configuration includes: PCMTIM, PCMCPU, PCMZPM, and the power supply
PCMPS2. For PCM systems with satellites (more than 9 zones), the number of modules and power supplies will increase as follows:
# ZONES
# PCMTIM
# PCMCPU
# PCMZPM*
# PCMPS2
1
to 9
1
1
1
to 3
1
1
0 to 18
1
2
4 to 6
2
1
9 to 27
1
3
7 to 9
3
28 to 36
1
4
1
0 to 12
4
37 to 45
1
5
1
3 to 15
5
46 to 54
1
6
1
6 to 18
6
55 to 63
1
7
1
9 to 21
7
64 to 72
1
8
22 to 24
8
73 to 81
1
9
25 to 27
9
82 to 90
1
1
0
28 to 30
1
0
91 to 99
1
11
31 to 33
11
Notice that for every 9 zones, one additional PCMCPU and one additional PCMPS2 are needed.
* 1 PCMZPM for every 1-3 paging zones.
INSTALLATION:
STEP 1: Assembling Master Modules PCMTIM to PCMCPU and to PCMZPM
•
Follow the same procedure described previously on page 5, step 1.
Note: Do NOT connect the PCMPS2 (power supply) at this point.
STEP 2: Assembling Satellite Modules PCMCPU to PCMZPM (see Illustration on page 38)
•
Plug the 6-pin power connector from the PCMZPM module to the PCMCPU module jack (J2.) Be sure that the locking ridge faces the
header wall. (Green wire to the top).
•
Plug the 26-pin ribbon cable from the PCMZPM module to the PCMCPU module 26-pin connector (J1). Be sure to align the polarizing
tab in slot. (Pin 1 red stripe to the top).
•
The satellite systems are usually installed below the the master assembly and must be within 3 feet of each other.
•
Use an RCA cable to connect the PCMCPU modules from DATA LINK to DATA LINK RCA connectors. (See drawing.)
STEP 3: Switch Settings
•
Set the TEL-INT-SEL DIP switches on the PCMTIM module to match the paging output access from the telephone system based on the
type of telephone interface used. (See step 3 on page 5 if using Page Port Contact Closure; page 7 for Page Port VOX; page 9 for Loop
Start Trunk; page 11 for Ground Start Trunk; or page 13 for Station Level/Centrex.)
•
Set the SYS-ID DIP switches on the master PCMCPU module to the OFF position (to the left).
•
Set the SYS-ID DIP switches on the first satellite PCMCPU module to the following configuration: Switch 1 to the ON position (to the
right). Switches 2, 3, & 4 to the OFF position (to the left). See SYS-ID switch settings chart on page 38 for additional satellite systems.
•
Set the RUN-PROGRAM switch on the PCMCPU module to the RUN mode (up).
•
Set the TALK BACK switches on the PCMZPM modules to the OFF position (to the left) for all zones.
•
Set the OUTPUT switch on all the PCMZPM modules to the HI-PWR position (down).
STEP 4: Testing your System
•
Connect one PCMPS2 power supply to each PCMCPU module either by the power jack 12V DC input or wire it to the 12V DC screw
terminals, observing polarity.
•
At this point all the power LEDs should be lit on each module.
•
Access the paging from the phone system and verify access tones (double beep).
•
At this point, the system should be functioning properly.
•
Disconnect Power Supply.
STEP 5: Connecting the Paging Amplifier
•
Locate the terminals on both PCMCPU modules labeled PA OUT/RT and wire them to the COMMON and 25V or 70V output on the
Bogen paging amplifier (either TPU-Series, GS-Series or Classic Series).
•
Locate the terminals on the PCMCPU modules labeled PA IN/RT and wire to the TIP and RING input on the Bogen paging amplifier.At
this point, the amplifier is connected in parallel to the master PCMCPU module and the satellite PCMCPU module.
STEP 6: Connecting 25/70V AC Speakers
•
Follow the same procedure described previously on page 5, step 6.
STEP 7: Testing your System
•
Follow the same procedure described previously on page 5, step 7.
26
15
PCM
TIM
PO
WER
TO
N
E
V
OLUME
BGM SRC
V
OLUME
GND ST
IN
RT
BGM
SRC
NIGHT
RING
TEL
LINE
O
VER
RIDE
NC
COM
NO
NC
COM
NO
RL
Y
ONE
RL
Y
TW
O
S1
S2
S3
S4
S5
S6
S7
TEL
INT
SEL
0 1
G
BK
R
Y
BL
W
Not used
Pla
y status contact common
A
udio output (-)
A
udio output (+)
Pla
y status contact
Not used
6 CONDUCT
OR
MODULAR
CABLE
RJ 11
MODULAR
BO
X
8
600
DL
LS
V
OLUME
1 6
1 6
1 2 3 4 5 6 7 8 9 101112
1 2 3 4 5 6 7 8 9 10 11 12
IN USE PLA
Y RECORD
PO
WER
12VDC 1A
COMPLIES
WITH P
AR
T 68, FCC R
ULES
FCC REGISTRA
TION NUMBER:
CD23CH-17705-KX-N
RINGER EQ
UIV
ALENCE:
1.2 B
T
AM B
TELEPHONE A
CCESS
MODULE
BOGEN
COMMUNICA
TIONS
RAMSEY
, NJ
MODE
24
VDC PWR SUPPL
Y
48
VDC PWR SUPPL
Y
CONFIRMA
TION T
ONE
PREANNOUNCE T
ONE
V
O
X DISABLE
V
O
X ENABLE
OFF
-----
S1, S2
S3
S4
S5
-----
ON
S1, S2
-----
S4
S3
-----
S5
PHONE SYSTEM
T
R
+M
-M
EXT V
O
X
ENABLE
PT
PR
P
A
GING OUTPUT
N.O
.
COM
CONT
A
CT CLOSURE A
+24/48
-24/48
PO
WER SUPPLIES
MODE
SWITCHES
BGM
VO
L
.
BGM
IN
TO
N
E
VO
L
U
M
E
MIN
MAX
V
O
X DELA
Y
MIN
MAX
P
A
GING TIME
MIN
MAX
OFF ON
G
BK
R
Y
BL
W
DFT120
PBX
ANALOG LINE
Note Switch settings:
Off - Up
, On - Do
wn
24/48V DC
PO
WER
SUPPL
Y
SETUP FOR CONFIGURATION 12: DFT120 & TAMB WIRING DIAGRAM - LOOP START TRUNK, GROUND START TRUNK OR STATION LEVEL