GeoDesy FSO Next series User Manual
Page 28

GeoDesy Kft.
H-1116 Budapest, Kondorfa str. 6
Pronto-X extra MGM functions
Additional functions
Transmitter on and off: you can switch the transmitters on and off separately
ACM: (aperture control mechanism
Default: auto mode, the system will automatically regulate the incoming light to the
optimal level of Udet, preventing the system to get oversaturated.
Manual: The incoming light can be regulated manually, the use of the
is strongly suggested during installation. The controller won’t start the regulation of
the incoming light, so the alignment will be much more accurate. (it can be set by
doing an unfinished booting during log in so we do not have to log on to
during the installation process).
Calibrating: it is an extra service. Some silencing settings can be made manually
(according to the scale) and the motor can also be skipped manually via the web. In
order to see where the motor is there are
calibration of the length of the circuit between the two end station in order to see
how many steps are left. Follow
Telefon: 06
. 6-8.
E-mail: info@geodesy
http://www.
28
X extra MGM functions
Transmitter on and off: you can switch the transmitters on and off separately
aperture control mechanism)
Default: auto mode, the system will automatically regulate the incoming light to the
optimal level of Udet, preventing the system to get oversaturated.
Manual: The incoming light can be regulated manually, the use of the
is strongly suggested during installation. The controller won’t start the regulation of
the incoming light, so the alignment will be much more accurate. (it can be set by
doing an unfinished booting during log in so we do not have to log on to
during the installation process).
Calibrating: it is an extra service. Some silencing settings can be made manually
(according to the scale) and the motor can also be skipped manually via the web. In
order to see where the motor is there are cadences. The system has to make a
calibration of the length of the circuit between the two end station in order to see
how many steps are left. Follow-up calibration can be made with the calibrate button.
Telefon: 06-1-481-2050
Fax.: 06-1-481-2049
http://www.geodesy-fso.com
Transmitter on and off: you can switch the transmitters on and off separately.
Default: auto mode, the system will automatically regulate the incoming light to the
Manual: The incoming light can be regulated manually, the use of the manual mode
is strongly suggested during installation. The controller won’t start the regulation of
the incoming light, so the alignment will be much more accurate. (it can be set by
doing an unfinished booting during log in so we do not have to log on to the web
Calibrating: it is an extra service. Some silencing settings can be made manually
(according to the scale) and the motor can also be skipped manually via the web. In
cadences. The system has to make a
calibration of the length of the circuit between the two end station in order to see
up calibration can be made with the calibrate button.