Gast 1534 Series Oilless Vacuum Pumps and Compressors User Manual
Page 12
TROUBLESHOOTING CHART
www.gastmfg.com
ISO 9001 & 14001 CERTIFIED
PART NO. 70 - 205 G335PL
(REV-G)
Low
High
Pump
Motor
Reason and remedy
Vacuum
Pressure
Vacuum
Pressure
Overheat
Overload
for problem.
•
•
At pump
•
•
Filter dirty.
Clean or replace.
•
At pump
•
•
Muffler dirty.
Clean or replace.
•
At pump
•
•
Vacuum line collapsed.
Repair or replace.
•
•
•
Relief valve set too high.
Inspect and adjust.
•
•
Relief valve set too low.
Inspect and adjust.
•
•
At pump At pump
•
•
Plugged vacuum/pressure line.
Inspect and repair.
•
•
Vanes sticking.
Clean or replace.
•
•
Vanes worn.
Replace.
•
•
•
•
Dust or offset powder in pump.
Inspect and clean.
•
•
•
•
Motor not wired correctly.
Check wiring diagram and line voltage.
We have Gast Certified Service Centers throughout the world.
For the most up-to-date
listing, contact one of our sales offices below:
Gast Manufacturing, Inc.
P.O. Box 97
2300 S. Highway M139
Benton Harbor, MI 48922
Ph: 269/926-6171
FAX: 269/925-8288
www.gastmfg.com
European Sales &
Service Headquarters
Gast Group Limited
A Unit of IDEX Corporation
Unit 11, The I O Centre
Nash Road
Redditch B98 7AS
United Kingdom
Tel: +44 (0) 1527 504040
Fax: +44 (0) 1527 525262
www.gastmfg.com
www.jun-air.com
Gast Hong Kong
Unit 12, 21/F, Block B
New Trade Plaza
6, On Ping Street, Shatin
N. T. Hong Kong
Ph: (852) 2690 1066
Fax: (852) 2690 1012
www.gasthk.com
- 1034 Series Oilless Vacuum Pumps and Compressors 1033 Series Oilless Vacuum Pumps and Compressors 0533 Series Oilless Vacuum Pumps and Compressors 3032 Series Oilless Vacuum Pumps and Compressors 2032 Series Oilless Vacuum Pumps and Compressors 1532 Series Oilless Vacuum Pumps and Compressors 1032 Series Oilless Vacuum Pumps and Compressors 1531 Series Oilless Vacuum Pumps and Compressors