TROUBLESHOOTING CHART

www.gastmfg.com

ISO 9001 & 14001 CERTIFIED

PART NO. 70 - 205 G335PL

(REV-G)

Low

High

Pump

Motor

Reason and remedy

Vacuum

Pressure

Vacuum

Pressure

Overheat

Overload

for problem.

At pump

Filter dirty.
Clean or replace.

At pump

Muffler dirty.
Clean or replace.

At pump

Vacuum line collapsed.
Repair or replace.

Relief valve set too high.
Inspect and adjust.

Relief valve set too low.
Inspect and adjust.

At pump At pump

Plugged vacuum/pressure line.
Inspect and repair.

Vanes sticking.
Clean or replace.

Vanes worn.
Replace.

Dust or offset powder in pump.
Inspect and clean.

Motor not wired correctly.
Check wiring diagram and line voltage.

We have Gast Certified Service Centers throughout the world.