beautypg.com

Gast 0211 Series Oilless Vacuum Pumps and Compressors User Manual

0211 series oil-less vacuum pumps & compressors, Peration, Aintenance

background image

0211 SERIES OIL-LESS

VACUUM PUMPS & COMPRESSORS

O

PERATION

& M

AINTENANCE

M

ANUAL

Product Use Criteria:

• Pump only clean, dry air.

• Operate at 32ºF - 104ºF (0ºC - 40ºC).

• Protect unit from dirt & moisture.

• Do not pump flammable or explosive gases or

use in an atmosphere that contains such gases.

• Protect all surrounding items from exhaust air. This

exhaust air can become very hot.

• Corrosive gases and particulate material will

damage unit. Water vapor, oil-based contaminants

or other liquids must be filtered out.

• Consult your Gast Distributor before using at high

altitudes.

• Oil-Less rotary-vanes require NO lubrication.

• Sealed bearings are grease packed.

• Use of petroleum or hydrocarbon products will

reduce carbon-vane service life.

Thank you for purchasing this Gast product. It is manufactured to the highest standards

using quality materials. Please follow all recommended maintenance, operational

and safety instructions and you will receive years of trouble free service.

General information

• Model numbers ending in “X”

have automatic thermal

protectors which protect the motor by shutting the motor

off if it overheats. The motor will automatically restart

once the motor has cooled.

www.gastmfg.com

ISO 9001 & 14001 CERTIFIED

PART NO. 70 - 160 G320PL (REV-E)

PLEASE READ THIS MANUAL COMPLETELY BEFORE INSTALLING AND USING

THIS PRODUCT. SAVE THIS MANUAL FOR FUTURE REFERENCE AND

KEEP IN THE VICINITY OF THE PRODUCT.