Problem
Possible Cause
Solution
6. Control valve stalled in
regeneration
a. Motor not operating
a. Replace motor
b. No electric power at outlet
b. Repair outlet or use working outlet
c. Defective transformer
c. Replace transformer
d. Defective PC board
d. Replace PC board
e. Broken drive gear or drive cap
assembly
e. Replace piston kit assembly
f. Broken piston retainer
e. Replace piston kit assembly
g. Broken main or regenerant piston
g. Replace piston kit assembly
7. Control valve does not
regenerate automatically when
REGEN
button is depressed and
held
a. Transformer unplugged
a. Connect transformer
b. No electric power at outlet
b. Repair outlet or use working outlet
c. Broken drive gear or drive cap
assembly
c. Replace piston kit assembly
d. Defective PC board
d. Replace PC board
8. Control valve does not
regenerate automatically but
does when
REGEN
button is
depressed
a. Bypass valve in bypass position
a. Put control valve in service position
b. Meter connection disconnected
b. Connect meter to PC board
c. Restricted/stalled meter turbine
c. Remove meter and check for rotation or
foreign material
d. Defective motor
d. Replace meter
e. Defective PC board
e. Replace PC board
f. Set-up error
f.
Check control valve set-up procedure
9. Time of day flashes on and off
a. Power has been out more than
two hours
a. Reset the time of day
b. The transformer was unplugged
and then plugged back into the
wall outlet
b. Reset the time of day
c. The transformer plug was
unplugged and then plugged back
into the board
c. Reset the time of day
d. The
NEXT
and
REGEN
buttons
were pressed to reset the valve
d. Reset the time of day