beautypg.com

Feiss P1113 User Manual

Assembly instructions for p1113, E) 4/07

background image

(E) 4/07

ASSEMBLY INSTRUCTIONS FOR P1113

IMPORTANT

TURN OFF THE POWER AT THE MAIN FUSE

OR CIRCUIT BREAKER BOX

BEFORE STARTING INSTALLATION

Bulb

(not included)

Canopy

(Fixture Plate)

Shade

Carefully unpack and identify all parts before assembly.

Bulbs are not included.

1. Install stems:

A. Choose desired installation height from any

combination of stems provided. Additional stems can

be purchased to increase installation height. However

do not add more stems than will allow 6" (15 cm) of

fixture wires above fixture plate.

B. Thread fixture wires through a center pipe. Install

center pipe by screwing into coupler.

C. Slip square stem through the installed center pipe.

Note correct position of stem from left diagram.

D. Lock stem into position by fastening with a lock

washer and coupler onto protruding center pipe. Note:

make certain center pipe is protruding about 3/8" (10

mm) above stem. If not then twist center pipe to loosen

in order to increase to desired height.

E. Repeat above steps B - D for additional stems.

F. For flat ceiling: After final stem installation, install

fixture plate on top of stem by fastening with lock

washer and hex nut onto protruding center pipe.

For vaulted ceiling (kit included in hardware bag):

After final stem installation, install hook on top of stem

by screwing onto protruding center pipe. Install short

threaded pipe into loop. Install loop onto bottom of

fixture plate by fastening with lock washer and hex nut

from above. Thread fixture wires through installed loop

center hole. Then while pulling wires from above,

attach hook onto loop.

2. Measure 6" of wire from end of fixture plate and cut off

remaining wire. Split wires and strip off 3/4" of

insulation from each end.

3. Follow enclosed "Multiple Standard Installation

Instructions" for electrical and fixture installation onto

ceiling junction box.

4. Place Shade over threaded socket then spacer tube and

secure with counter ring, using supplied wrench.

5. Install bulbs (not included). See relamping label located

at socket area for type and maximum allowed wattage.

Counter Ring

Socket

Fixture Wires

& Ground Wire

Hex Nut

Lock Washer

Ball Cap Nut

Short

Threaded

Pipe

Canopy

Loop

Hook

Stem

VAULTED CEILING

INSTALLATION

Center Pipe

Coupler

Coupler

Square Stems

(3) 12 in. long

(1) 6 in. long

Lock

Washer

Spacer Tube

Wrench

(included)