(E) 10/04
ASSEMBLY I NSTRUCTI ONS FOR F1904/4
M U R R A Y F E I S S
©MURRAY FEI SS I MPORT LLC.
Bulb
(not included)
Socket
Font
FIG: 1 CHAIN HUNG INSTALLATION
FIG: 2 FLUSH MOUNT
INSTALLATION
Mounting Plate
Machine Screws
Note: Spare crystals enclosed in hardware bag.
Fixture Wire
and Ground Wire
Fixture Loops
Threaded
Chain Link
Fixture Plate
Canopy Loop
Ball Cap
Nuts
Chain
Threaded
Chain Link
Candle Tube
Hex Nut
Lock Washer
Fixture plate
Short
Threaded
Pipe
Fixture Wire
& Ground Wire
Canopy Loop
Ball Cap Nut
IMPORTANT TURN OFF POWER AT MAIN FUSE OR
CIRCUIT BREAKER BOX BEFORE
STARTING INSTALLATION
Carefully unpack and identify all parts before assembly.
Bulbs are not included.
1. Place candle tubes over candelabra sockets and screw
bulbs (not included) into sockets to secure. See relamping
label on candle tube for type and maximum
allowed wattage.
2. Install font by screwing into bottom of fixture.
3. Hang all crystal glass parts as shown on drawing.
NOTE: To replace broken crystals or pins extras are
included in hardware bag. To replace broken crystals
open pins, remove crystal, hook new one, then close
back pin. Avoid bending pins into sharp angle.
4. This fixture can be mounted onto ceiling either as
chain hung or flush mount:
CHAIN HUNG INSTALLATION- Fig. 1:
A. Take fixture wire (with plastic insulation) and
ground wire and thread through fixture loop. Then
install loop onto threaded pipe located at top of fixture.
B. This fixture is supplied with 2 threaded chain links.
These links are opened and closed by twisting cylinder
on chain link. One threaded chain link should be
installed onto canopy loop and the other should be
installed onto fixture loop. The standard chain should
be installed in between these 2 threaded chain links.
C. Determine the desired length of chain to hang.
Remove any unwanted links with chain plier.
D. Take ground wire and weave through above chain
links, then thread through center hole in canopy loop.
Repeat with fixture wire (wire with plastic insulation).
FLUSH MOUNT INSTALLATION- Fig. 2:
A. Remove and discard canopy loop and threaded pipe
from fixture plate.
B. Thread ground wire and fixture wire through fixture
plate, lock washer, and hex nut. Lock all together on
top of fixture by tightening hex nut onto threaded pipe.
5. Cut excess wires leaving only 6" (15cm) length of
wires above canopy. Split fixture wire into two strands.
Then strip off 3/4" (19mm) of outer plastic insulation.
6. Follow enclosed “Multiple Standard Installation
Instructions” for electrical and fixture installation onto
ceiling outlet box.
NOTE: Before starting wire connection, enlist a helper to
support the fixture, or make a hook from a wire coat hanger
and temporarily suspend the fixture from mounting plate.
2
2
1
3
1
1
2
(8) PC.
1
(12) PC.
3