Feiss FM257 User Manual
E) 03/06
(E) 03/06
ASSEMBLY I NSTRUCTI ONS FOR FM256, FM257
IMPORTANT
TURN OFF THE POWER AT THE MAIN FUSE
OR CIRCUIT BREAKER BOX
BEFORE STARTING INSTALLATION
Carefully unpack and identify all parts before assembly.
Bulb not included.
1.
Install glass panels:
A. Take one glass panel and carefully slip through
inside of main frame. Position it so both side edges
of the panel are located hidden behind vertical ribs
of the main frame.
B. Lock the glass panel by bending tabs located at
top and bottom of main frame.
C. Repeat other glass panels.
2.
Attach mounting bar securely to ceiling junction box
with two machine screws (supplied with junction
box) through slot at each end of mounting bar.
Note: mounting bar should be installed with "GND"
imprint and/or two dimples facing down.
3.
Fasten one hex nut about 3/4" (19 mm) down from
one end of threaded pipe. Then screw same end of
threaded pipe into center hole in mounting bar. At
this point test install the main frame onto ceiling
through this threaded pipe and make certain 3/8"
(10 mm) of pipe protrude below. If not, then adjust
the threaded pipe location by screwing up or down
accordingly. Once correct threaded pipe location has
been adjusted, remove main frame and tighten hex
nut against mounting bar. Make certain not to spin
threaded pipe during tightening.
4.
Spread the electrical wires so that the black
wires are on one side of the outlet box and
the white wires are on the other side.
5.
Electrical connections:
Connect the white wire from the fixture to the white
wire of the outlet box. Connect the black wire from
the fixture to the black wire of the outlet box.
NOTE: Black outlet box wire may be red, round &
smooth and/or have copper conductor. White outlet
box wire may be square & ridged and/or have a
silver conductor.
6.
Grounding Connection:
Connect fixture ground wire (without insulation) to
ground wire from outlet box (usually with green
insulation) with wire connector (not provided).
IMPORTANT: Never connect ground wire to black
or white power supply wires.
7.
While making certain all electrical wires are tucked
inside of main frame, install the main frame by
fastening with a lock washer and coupler onto the top
threaded pipe.
8.
Install bulb (not included). See relamping label
located at socket area for type and maximum
allowed wattage.
9.
Install the center pipe by screwing onto bottom of
main frame. Note correct position of center pipe
at illustration.
10.
Install glass plate by slipping through the already
installed center pipe and then fastening with a finial.
IMPORTANT: Do not over tighten.
M U R R A Y F E I S S
©MURRAY FEI SS I MPORT LLC.
A Quality Home Brands Company®
Outlet Box
Hex Nut
Outlet Box
Mounting Screw
(not supplied)
Mounting
Bar
Supply
Ground Wire
Supply
Wires
Fixture
Wires
Fixture
Ground Wires
Finial
Socket
Main
Frame
Glass Panel
Center Pipe
Glass Plate
Lock Washer
Coupler
1
2
3
4
5
7
8
9
10
Bulb
(not included)
6