Fm355, Assembly instructions for
IMPORTANT
TURN OFF THE POWER AT THE MAIN FUSE OR
CIRCUIT BREAKER BOX
BEFORE STARTING INSTALLATION
Carefully unpack and identify all parts before
assembly.
Bulbs not included.
1. Install mounting plate:
A. Fasten two long machine screws (supplied) into
opposite side of the mounting plate from green
grounding screw head.
B. Take supply wires from outlet box and carefully pass
them through center hole of mounting plate.
C. Install mounting plate onto the outlet box using two
screws supplied with outlet box.
D. Test install fixture plate to make certain about 1/4”
(5mm) of screws thread protrude outside of fixture
plate. If not then remove fixture plate and adjust screws
length accordingly. Secure screws length by fastening
with two hex nuts. Make certain not to spin screws
during fastening. Place fixture plate aside.
E. Spread electrical wires so that black wires are on one
side of the outlet box and the white wires are on the
other side.
2. Connect electrical wires:
A. Connect white fixture wire to white supply wire
from outlet box with wire connector. Connect black
fixture wire to black supply wire from outlet box with
wire connector.
NOTE: Black outlet box wire may be red, round and
smooth and/or have copper conductor. White outlet
box wire may be square and ridged and/or have a silver
conductor.
B. Connect fixture ground wire (without plastic
insulation) to ground wire from outlet box (usually with
green insulation) with wire connector.
Note: If there is no supply ground wire at outlet box
then attach fixture ground wire securely onto green
grounding screw located at mounting plate.
IMPORTANT: Never connect ground wire to black or
white supply wires (from outlet box).
3. While carefully tucking all electrical wires inside the top
of the fixture, install the fixture onto the mounting plate
by fastening with two cap nuts.
4. Install center pipe by screwing into coupler. Note
correct position of center pipe at illustration.
5. Install bulb (not included). See relamping label located at
socket area for type and maximum allowed wattage.
6. A. Slide shade and glass diffuser through the threaded
pipe until shade comes to a stop.
B. Secure shade and glass diffuser into position by
fastening with a spacer and a hex nut. IMPORTANT:
DO NOT OVER TIGHTEN.
C. Secure by fastening finial.
Assembly Instructions For
FM355
(E) 5/10
2
3
4
6A
6B
6C
5
1