Feiss FM324 User Manual
Fm324, Assembly instructions for
IMPORTANT
TURN OFF THE POWER AT THE MAIN FUSE OR
CIRCUIT BREAKER BOX
BEFORE STARTING INSTALLATION
Carefully unpack and identify all parts before
assembly. Bulb
not included.
1. Attach mounting bar securely to ceiling junction box with
two machine screws (supplied with junction box) through
slot at each end of mounting bar. Note: mounting bar should
be installed with "GND" imprint and/or two dimples facing
down.
2. Fasten one hex nut about 3/4" (19 mm) down from one end
of threaded pipe. Then screw same end of threaded pipe into
center hole in mounting bar. At this point test install the pan
onto ceiling through this threaded pipe and make certain 3/8"
(10 mm) of pipe protrude below. If not, then adjust the
threaded pipe location by screwing up or down accordingly.
Once correct threaded pipe location has been adjusted,
remove pan and tighten hex nut against mounting bar. Make
certain not to spin threaded pipe during tightening.
3. Spread the electrical wires so that the black wires are on one
side of the outlet box and the white wires are on the other
side.
4. Electrical connections:
Connect the white wire from the fixture to the white wire of
the outlet box. Connect the black wire from the fixture to
the black wire of the outlet box.
NOTE: Black outlet box wire may be red, round & smooth
and/or have copper conductor. White outlet box wire may be
square & ridged and/or have a silver conductor.
5. Grounding Connection:
Connect fixture ground wire (without insulation) to ground
wire from outlet box (usually with green insulation) with
wire connector (not provided).
IMPORTANT: Never connect ground wire to black or white
power supply wires.
6. Place pan thru top threaded pipe so that it sits flush against
ceiling. Be sure all wires are inside pan. Secure pan to ceiling
by fastening lock washer and coupler onto top threaded pipe.
Note: Coupler must turn at least 3 times, if it does not you
must remove coupler and lengthen threaded pipe accordingly.
7. Install bulb (not included). See relamping label located at
socket area for type and maximum allowed wattage.
8. Install a hex nut onto one end of long threaded pipe leaving
about 1/2" (13 mm) thread exposed. Screw same end of
threaded pipe into coupler. Tighten hex nut.
9. Slip glass shade up till it checks into bottom of pan. Then lock
into position by fastening with flat washer and hex nut. Do
not over tighten.
10. Slip lower font through same threaded pipe and secure by
fastening with finial.
Assembly Instructions For
FM324
Mounting Bar
Outlet Box
Mounting Screw
Socket
Bulb
(not included)
Threaded Pipe
Cover
Finial
Supply Ground Wire
Supply Wire
Fixture Ground Wire
Fixture Wire
Shade
Pan
Lock Washer
Coupler
(E) 11/08
Long
Threaded Pipe
Flat Washer
Hex Nut