Feiss FM334 User Manual
Fm334, Assembly instructions for
IMPORTANT
TURN OFF THE POWER AT THE MAIN FUSE OR CIRCUIT
BREAKER BOX BEFORE STARTING INSTALLATION
Carefully unpack and identify all parts before
assembly. Bulb not
included.
1. Install glass panels: (see fig. 1)
A. Gently grabbing onto a glass panel, slip inside of main frame.
Make certain top edge of panel check onto upper tabs located at
inside of main frame
B. Secure glass panel by bending tabs located at bottom.
C. Repeat rest panels.
2. Gently pull supply wires out from ceiling outlet box.
3. Attach mounting strap securely to ceiling outlet box with two
machine screws (supplied with outlet box) through slot at each end
of mounting strap. Note: mounting strap should be installed with
"GND" imprint and/or two dimples facing down.
4. Fasten one hex nut about 3/4" (19 mm) down from one end of
threaded pipe. Then screw same end of threaded pipe into center
hole in mounting strap. At this point test install the main frame onto
ceiling through this threaded pipe and make certain 3/8" (10 mm) of
pipe protrude below. If not, then adjust the threaded pipe location by
screwing up or down accordingly. Once correct threaded pipe
location has been adjusted, remove main frame and tighten hex nut
against mounting strap. Make certain not to spin threaded pipe
during tightening.
5. Spread the electrical wires so that the black wires are on one side of
the outlet box and the white wires are on the other side.
6. Electrical connections:
Connect the white wire from the fixture to the white wire of the
outlet box.
Connect the black wire from the fixture to the black wire of the
outlet box.
NOTE: Black outlet box wire may be red, round & smooth and/or
have copper conductor. White outlet box wire may be square &
ridged and/or have a silver conductor.
7. Grounding Connection:
Connect fixture ground wire (without insulation) to ground wire
from outlet box (usually with green insulation) with wire connector
(not provided).
Note: If there is no supply ground wire at outlet box then attach
fixture ground wire securely onto green grounding screw located at
mounting strap.
IMPORTANT: Never connect ground wire to black or white supply
wires (from outlet box).
8. Place main frame through top threaded pipe so that it sits flush
against ceiling. Be sure all wires are tucked inside. Secure main frame
to ceiling by fastening lock washer and coupler onto top threaded
pipe.
Note: Coupler must turn at least 3 times, if it does not you must
remove coupler and lengthen threaded pipe accordingly.
9. Install long threaded pipe by screwing into bottom of coupler. Note
correct position of center pipe at illustration.
10. Install bulb (not included). See relamping label located at socket area
for type and maximum allowed wattage.
11. Slip glass plate through long threaded pipe until it checks inside of
main frame. Lock glass plate by fastening finial. IMPORTANT: Do not
over tighten.
Assembly Instructions For
FM334
(E) 5/09
7
2 5
6
3
4
1A
1B
10
11
8
9