7 Status messages

00

hex

:

No error

02

hex

:

Data carrier not in active range

03

hex

:

Read operation aborted
or
Parity bit error for data carrier read-only

04

hex

:

Error while programming or while check-reading the data carrier

05

hex

:

Write operation aborted.
(Data carrier moved out of active range during write operation)

06

hex

:

Write operation aborted.
Start address or number of bytes is not a multiple of the block size "4"

07

hex

:

Data carrier is out of active range (in TG mode only)

16

hex

:

Data length larger than 16 bytes

18

hex

:

Read attempt if EKS is set on data carrier read-only and data carrier read/write
is inserted

1D

hex

:

Read operation of a data carrier read-only with a set “number of bytes user
data” more than 5 bytes, or the start address of user data is

¹ byte 0

4X

hex

:

General error.
Try once again to read or write the data carrier

42

hex

:

Error during programming data carrier read/write.
Data carrier in read
range but not in write range