Combination options, Connection table – EUCHNER ESM User Manual
Page 6
Operating Instructions Read Heads/Actuators for Safety Relays ESM
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49 711 7597-0 Fax +49 711 753316 [email protected] www.euchner.de
Figure 2: Dimension drawings for read heads CMS-R-AZA... / CMS-R-AZC-SC /
CMS-R-BZB... / CMS-R-BZB-SC
Dimension drawings actuator CMS-M-AI / CMS-M-BH
The dimensions of the actuators are the
same as those of the read heads, although
the former have no connection cable/plug
connector.
CMS‑R‑BZB
CMS‑M‑BH
2,5
2,5
S
ao
19,
2
26,
2
22
7
36
13
5
8,5
4,5
42
ca.
5,
8
∅
0,34 mm²
5,7
12,9 ±0,25
= =
17
9,
2
M8
1
4
2
3
Actuator
Active face
Center offset m at s = 3 mm
Connector assignment
View of connection side
CMS‑R‑BZB‑SC
2,5
2,5
S
ao
78
±0,1
∅ 5,5
9,
5
25
12
6
6
67,5
87,5
2,
5
13
42
ca.
5,
8
∅
7,2 ±0,25
M8
7,2
5
4
3
1
2
CMS‑R‑AZA
CMS‑M‑AI
Actuator
Active face
Center offset m at s = 3 mm
Yellow LED indicator
Only on version CMS‑R‑AZA
2,5
2,5
S
ao
78
±0,1
∅ 5,5
9,
5
25
12
6
6
67,5
87,5
2,
5
13
42
ca.
5,
8
∅
7,2 ±0,25
M8
7,2
5
4
3
1
2
Connector assignment
View of connection side
CMS‑R‑AZC‑SC
CMS‑R‑AZA‑ST0,2VL
205,5
47
2
1
6
5
4
3
8 NC
7 NC
Yellow LED indicator
Connector assignment
View of connection side
Plug connector M12
Combination options
Design
Read head
Circuit
diagram not
actuated
1)
Actuator
Assured
switch‑on
distance s
ao
[mm]
2)
Assured
switch‑off
distance s
ar
[mm]
Evaluation units ESM
‑BA2.. and ESM
‑BA3..
3)
CMS‑R‑AZA
BN
WH
BK (YE)
PK
GY
BU (GN)
F2
F1
Rv
CMS‑M‑AI
9
(7)
4)
20
(15)
4)
CMS‑R‑AZA‑ST0,2VL
1
2
4
5
6
3
F2
F1
Rv
CMS‑M‑AI
9
(7)
4)
20
(15)
4)
CMS‑R‑AZC‑SC
1
2
4
3
F2
F1
CMS‑M‑AI
9
22
CMS‑R‑BZB
CMS‑R‑BZB‑SC
BN
WH
BK (YE)
BU (GN)
1
2
4
3
F2
F1
CMS‑M‑BH
7
20
1) Old conductor coloring in brackets.
2) There must be no ferromagnetic material in the vicinity of the read head or the actuator.
All data refer to the frontal approach direction and a center offset of m = 0.
3) The LED for the contact status indication has an internal series resistor of 1.5 k
Ω.
4) Operating distance for contact status indication and LED.
Hilfs-
kontakt/
auxilliary
contacts
Start
0V
A2
UB
A1
Sicherheits-
kontakte/
safety
contacts
AC
AC
LOGIC
-K1
S21
S11
ESM
13
33
14
34
23
24
41
42
S14
S12
S13
S10
-B1
BN
WH
BU
BK
PK
GY
CMS
Betätiger/actuator
Lesekopf/readhead
nur bei AC 115/230V
with AC 115/230V only
13
14
-S1
Figure 3: Connection example comprising ESM-BA3.., CMS-R-AZA... and CMS-M-AI
Connection table
Connection terminals
evaluation units
ESM‑BA2../ESM‑
BA3..
Read head connections
CMS‑R‑AZA...
CMS‑R‑AZC...
CMS‑R‑BZB...
S10
WH
2
WH / 2
S11 / S14
BK (YE)
3
BK (YE) / 3
S12
BU (GN)
4
BU (GN) / 4
S13
BN
1
BN / 1
Explanation of core colors
Designation acc. to DIN IEC 60757
BK
black
BN
brown
YE
yellow
GN
green
BU
blue
GY
gray
WH
white
PK
pink
0,34 mm²
(6 x 0,25 mm²
with CMS‑R‑AXR)