Figure 2: Dimension drawings for read heads CMS-R-AZA... / CMS-R-AZC-SC /

CMS-R-BZB... / CMS-R-BZB-SC

Dimension drawings actuator CMS-M-AI / CMS-M-BH

The dimensions of the actuators are the

same as those of the read heads, although

the former have no connection cable/plug

connector.

CMS‑R‑BZB

CMS‑M‑BH

2,5

2,5

S

ao

19,

2

26,

2

22

7

36

13

5

8,5

4,5

42

ca.

5,

8

0,34 mm²

5,7

12,9 ±0,25

= =

17

9,

2

M8

1

4

2

3

Actuator

Active face

Center offset m at s = 3 mm

Connector assignment

View of connection side

CMS‑R‑BZB‑SC

2,5

2,5

S

ao

78

±0,1

∅ 5,5

9,

5

25

12

6

6

67,5

87,5

2,

5

13

42

ca.

5,

8

7,2 ±0,25

M8

7,2

5

4

3

1

2

CMS‑R‑AZA

CMS‑M‑AI

Actuator

Active face

Center offset m at s = 3 mm

Yellow LED indicator

Only on version CMS‑R‑AZA

2,5

2,5

S

ao

78

±0,1

∅ 5,5

9,

5

25

12

6

6

67,5

87,5

2,

5

13

42

ca.

5,

8

7,2 ±0,25

M8

7,2

5

4

3

1

2

Connector assignment

View of connection side

CMS‑R‑AZC‑SC

CMS‑R‑AZA‑ST0,2VL

205,5

47

2

1

6

5

4

3

8 NC

7 NC

Yellow LED indicator

Connector assignment

View of connection side

Plug connector M12

Combination options

Design

Read head

Circuit

diagram not

actuated

1)

Actuator

Assured

switch‑on

distance s

ao

[mm]

2)

Assured

switch‑off

distance s

ar

[mm]

Evaluation units ESM

‑BA2.. and ESM

‑BA3..

3)

CMS‑R‑AZA

BN

WH

BK (YE)

PK

GY

BU (GN)

F2

F1

Rv

CMS‑M‑AI

9

(7)

4)

20

(15)

4)

CMS‑R‑AZA‑ST0,2VL

1

2

4

5

6

3

F2

F1

Rv

CMS‑M‑AI

9

(7)

4)

20

(15)

4)

CMS‑R‑AZC‑SC

1

2

4

3

F2

F1

CMS‑M‑AI

9

22

CMS‑R‑BZB

CMS‑R‑BZB‑SC

BN

WH

BK (YE)

BU (GN)

1

2

4

3

F2

F1

CMS‑M‑BH

7

20

1) Old conductor coloring in brackets.

2) There must be no ferromagnetic material in the vicinity of the read head or the actuator.

All data refer to the frontal approach direction and a center offset of m = 0.

3) The LED for the contact status indication has an internal series resistor of 1.5 k

Ω.

4) Operating distance for contact status indication and LED.

Hilfs-

kontakt/

auxilliary

contacts

Start

0V

A2

UB

A1

Sicherheits-

kontakte/

safety

contacts

AC

AC

LOGIC

-K1

S21

S11

ESM

13

33

14

34

23

24

41

42

S14

S12

S13

S10

-B1

BN

WH

BU

BK

PK

GY

CMS

Betätiger/actuator

Lesekopf/readhead

nur bei AC 115/230V

with AC 115/230V only

13

14

-S1

Figure 3: Connection example comprising ESM-BA3.., CMS-R-AZA... and CMS-M-AI

Connection table

Connection terminals

evaluation units

ESM‑BA2../ESM‑

BA3..

Read head connections

CMS‑R‑AZA...

CMS‑R‑AZC...

CMS‑R‑BZB...

S10

WH

2

WH / 2

S11 / S14

BK (YE)

3

BK (YE) / 3

S12

BU (GN)

4

BU (GN) / 4

S13

BN

1

BN / 1

Explanation of core colors

Designation acc. to DIN IEC 60757

BK

black

BN

brown

YE

yellow

GN

green

BU

blue

GY

gray

WH

white

PK

pink

0,34 mm²

(6 x 0,25 mm²

with CMS‑R‑AXR)