beautypg.com

Ordering information and accessories, Inspection and service, Service – EUCHNER CES-AH-C03-AH-SM (Unicode) User Manual

Page 25: Service 25

background image

Operating Instructions Safety Switch CES-AH-C03-AH-SM

25

Ordering information and accessories

Designation

Version

Order

no.

Safety Switch

CES-AH-C03-AH-SM-106300

Unicode

106 300

Actuator BBA

42 mm x 25 mm

071 840

Actuator BCA

42 mm x 25 mm

088 786

Actuator BPA

40 mm x 40 mm

098 775

Actuator BRN

80 mm x 40 mm

100 251

Mating connector

for evaluation unit

M23 9-pin

106 597

Inspection and service

Warning!

Loss of the safety function because of damage to the system.
In case of damage, the related safety component must be replaced. The replace-
ment of individual parts in a safety component is not permitted.

Regular inspection of the following is necessary to ensure trouble-free long-term

operation:

Ì

Check the switching function (see section Functional check)

Ì

Check the secure fastening of the devices and the connections

Ì

Check for soiling

No servicing is required, repairs to the device are only allowed to be made by the

manufacturer.

Note!

The year of manufacture can be seen in the lower right corner of the rating plate.

Service

If service support is required, please contact:

EUCHNER GmbH + Co. KG
Kohlhammerstrasse 16
D-70771 Leinfelden-Echterdingen
Service telephone:
+49 711 7597-500
E-mail:
[email protected]
Internet:
www.euchner.de