Operating Instructions Safety Switch CES-AH-C03-AH-SM
11
Connection cables and plug connectors
Caution!
Risk of damage to equipment or malfunctions as a result of incorrect connec-
tion cables.
Ì
Use EUCHNER connectors.
Ì
If other connection components are used, the following recommendations
apply. EUCHNER provides no warranty for safe function in case of failure to
comply with these requirements.
Ì
The maximum cable length should not exceed 50 m.
Recommended connection cable:
e.g. LiYY 7 x 1mm²,
Ölflex classic 400P 7 x 0.75
Mating connector for the evaluation unit:
EUCHNER M23, 9-pin, cable cross-section max. 1 mm² order no. 106 597
Alternative e.g.
Coninvers order no. RC-09S1N121600, cable cross-section max. 1 mm²
Important!
It is imperative you use the original tools from the connector manufacturer for
assembly and follow the assembly instructions from the connector manufacturer.
Connector assignment
1
2
3
4
5
9
6
7
8
Figure 1: Connector assignment safety switch CES-AH-C03-AH-SM
Pin
Designation
Description
1
NC
Not used *
2
Start
Start input
3
LA
Safety output, channel 1
4
+LA
Input for channel 1
5
+LB
Input for channel 2
6
LB
Safety output, channel 2
7
UB
Power supply, DC 24 V
8
0 V
Ground, DC 0 V
9
NC
Not used *
* The unused connection pins are not allowed to be connected by the user!
View of connection side