Ec declaration of conformity, Technical data – EUCHNER Hinge ESH Re-adjustable User Manual
Page 4

Operating Instructions Safety Hinge ESH Re-adjustable
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 Fax +49/711/75 33 16 www.euchner.de [email protected]
Subject to technical modifications; no r
esponsibility is accepted for the accuracy of this information. © EUCHNER GmbH + Co. 109804-03-11/11 (translation of the original operating instructions)
Exclusion of liability under the following
conditions:
incorrect use
non-compliance with safety regulations
installation and electrical connection not per-
formed by authorized personnel
failure to perform functional checks.
EC declaration of conformity
The manufacturer named below herewith declares
that the product fulfils the provisions of the
directive(s) listed below and that the related
standards have been applied.
EUCHNER GmbH + Co. KG
Kohlhammerstrasse 16
70771 Leinfelden-Echterdingen, Germany
Directives applied:
Machinery directive 2006/42/EC
Standards applied:
EN 60947-5-1:2004 + Cor.:2005 + A1:2009
EN 1088:1995+A2:2008
Leinfelden, July 2010
Dipl.-Ing. Michael Euchner
Director
Duc Binh Nguyen
Authorized representative empowered to draw up
documentation
The signed EC declaration of conformity is included
with the product.
Technical data
Parameter
Value
Housing material
Die-cast zinc
Degree of protection according
to IEC 60529
IP 67
Mech. operating cycles
1x10
6
Ambient temperature
-25 °C ... +70 °C
Degree of contamination (exter-
nal, according to EN 60947)
3 (industrial)
Installation position
Any
Weight
0.77 kg
Max. load as per mechanical
life test acc. to EN 1935
Grade 12
(100 kg door weight)
Pivoting angle
-10° … 180°
Operating point
4° from fixing point
Positively driven
Approx. 10° from fixing point
Actuation frequency
Max. 1200 operating cycles / h
Switching principle
Snap-action switching contact
Contact material
Silver alloy
Connection type
Plug connector M12 / 5-pin
Rated impulse withstand
voltage
2.5 kV
Rated insulation voltage
60 V
Conditional short-circuit current 100 A
Utilization category to EN 60947-5-1
AC-15
DC-13
1.5 A
30 V
2.0 A
24 V
Switching current, min., at 24V 1 mA
Short circuit protection (control
circuit fuse) according to IEC
60269-1
2 A gG
Conventional thermal current I
th
3 A
Reliability figures according to EN ISO 13849-1
B
10d
2 x 10
6
1
4
5
2
3
1
4
5
2
3
Version
ESH-ARO-20A-1205
Version
ESH-ARO-11A-1205
Figure 1: Pin assignment plug M12/5-pin
M12x1
SW14
SW
6
34
60
6,5
(4x)
16
16
12
12
50
42,5
50
27,4
17
9,4
12,9
84
115
100
14,50
Figure 2: Dimension drawing safety hinge ESH
Dimensions as supplied
Dimensions operating point fixed