Version STM.. (cable entry M20x1.5/NPT ½“, see
rating plate)
Fit the cable gland with the appropriate degree of
protection.
For pin assignment see Figure 2.
Tighten the screws with a torque of 0.5 Nm.
Check that the cable entry is sealed.
Close the cover and screw in position.
Functional Check
Warning! Danger of fatal injury as a result of faults
in installation and functional check.
Before carrying out the functional check, make sure
that there are no persons in the danger area.
Observe the valid accident prevention regulations.
After installation and any fault, the safety function must
be fully checked. Proceed as follows:
Mechanical function test
The actuator must slide easily into the actuating head.
Close the safety guard several times to check the
function.
Electrical function test
1. Switch on operating voltage.
2. Close all safety guards.
Guard locking by solenoid force: Activate guard
locking.
The machine must not start automatically.
It must not be possible to open the safety guard.
3. Enable operation in the control system.
It must not be possible to deactivate the guard locking
as long as operation is enabled.
4. Disable operation in the control system and deactivate
guard locking.
The safety guard must remain locked until there is no
longer any risk of injury.
It must not be possible to start the machine as long as
the guard locking is deactivated.
Repeat steps 2 - 4 for each safety guard.
Inspection and Service
If damage or wear is found, the complete switch
and actuator assembly must be replaced.
Replacement of individual parts or assemblies is
not permitted!
No servicing is required, but regular inspection of the
following is necessary to ensure trouble-free long-term
operation:
correct switching function
secure mounting of components
dirt and wear
sealing of cable entry
loose cable connections.
Safety switches STM must be exchanged completely after
2 millions operating cycles.
Note:The year of manufacture can be seen in the bottom,
right corner of the rating plate.
Exclusion of Liability under the Following
Conditions:
if the unit is not used for its intended purpose
non-compliance with safety regulations
non-compliance with safety regulations
failure to perform functional checks.
EC declaration of conformity
The manufacturer named below herewith declares that
the product fulfills the provisions of the directive(s) listed
below and that the related standards have been applied.
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen, Germany
Directives applied:
Machinery directive 2006/42/EC
Standards applied:
EN 60947-5-1:2004 + Cor.:2005 + A1:2009
EN 1088:1995+A2:2008
Leinfelden, July 2010
Dipl.-Ing. Michael Euchner
Director
Duc Binh Nguyen
Authorized representative empowered to draw up
documentation
The signed EC declaration of conformity is included with
the product.
Technical Data
Parameters
Value
Housing material
Reinforced thermoplastic
Degree of protection
according to IEC 60529
IP67
Mech. operating cycles
2 x 10
6
Ambient temperature
-20°C ... +55°C
Installation position
Any
Approach speed, max.
20 m/min
Actuation frequency, max.
7000 / h
Actuating force, max.
at 20°C
35 N
Extraction force (not locked)
30 N
Retention force
20 N
Locking force according to GS-ET-19 (in locked position)
Approach direction
side (h)
From top (v)
STM.E, ..F, ..G, ..H, ..N, ..O,..P, ..Q
700 N
700 N
STM.A, ..B, ..C, ..D
1,500 N
1,500 N
Locking force F
max
Approach direction
(in locked position)
Side (h)
From top (v)
STM.E, ..F, ..G, ..H, ..N, ..O,..P, ..Q
≥ 1,000 N
≥ 1,000 N
STM.A, ..B, ..C, ..D
≥ 2,000 N
≥ 2,000 N
with angled actuator
1,500 N
1,500 N
Weight
Approx. 0.88 lb
Switching principle
Slow-action switching contact
Contact material
Silver alloy, gold flashed
Connection type
Screw terminals M20 x 1.5
Conductor cross-section
(rigid/flexible)
0.34 ... 1.5 mm
2
Rated insulation voltage
U
i
= 250 V
Rated impulse withstand voltage U
imp
= 2.5 kV
Rated short-circuit current
100 A
Degree of contamination
(external, acc
3 (industrial) ording to
EN 60947-1)
Switching current, min., at 24 V
1 mA
Switching voltage, min., at 10 mA 12 V
Utilization category
to IEC 60947-5-1
AC-15 4A 230V / DC-13 4A 24V
Conventional thermal current I
th
4 A
Short circuit protection
4 A gG
Solenoid operating voltage
AC/DC 24 V (+10%/-15%) 6 W
Solenoid duty cycle ED
100 %
Solenoid power consumption
6 W
Reliability figures according to EN ISO 13849-1
B
10d
2 x 10
6
E2
E1
E1
E2
E1
E2
SK
ÜK
SK
ÜK
SK
ÜK
ÜK
SK
ÜK
SK
ÜK
SK
STM...222...
21
11
22
12
12
11
22
12
12
11
21
11
22
12
21
11
12
11
STM...242...
11
12
24
12
23
11
12
11
24
12
23
11
12
11
24
12
23
11
Figure 2: Switching elements and switching functions
Door closed and locked
Door closed and not locked
Door open
Version
Illustration: safety guard closed, actuator locked.
NC contact opens before NO contact closes (break before make).
(F
Zh
=
F
max
)
1,3