If using category 5 for dmx/rdm input, Canopy mounting plate installation – ETC Desire D22 User Manual
Page 6
![background image](/manuals/559134/6/background.png)
6
Desire Series D22
If using Category 5 for DMX/RDM input:
a:
Reference the Cat5 Cable Preparation for IDC Termination Setup Guide
for instructions to prepare and terminate Category 5 for DMX/RDM input
cable to the insulation displacement connector.
b:
Install the IDC connector with wires
terminated to the DMX/RDM Input
receptacle on the termination board.
Step 2:
Optionally, terminate DMX/RDM thru to the
next device in the DMX data run. Up to 32
DMX/RDM devices can be daisy-chained
together per data run. Refer to
.
a:
Reference the specific termination setup
guide for the type of cable used (either
Belden 9729 or Category 5) in the
installation. Termination kits are ordered
separately.
b:
Install the connector with wires terminated
to the DMX/RDM Thru receptacle on the
termination board.
Step 3:
Terminate DMX/RDM data signal for the last DMX/RDM device in the
data run by setting the termination switch on the termination board to ON.
All other devices in the data run maintain the factory default termination
switch setting OFF. Refer to
Canopy Mounting Plate Installation
Step 1:
Install the divider in the junction box
with the provided screw, separating
the power side from the data side.
Step 2:
Strip the supply power wires back 1/2
inch (13mm).
Step 3:
Use a #2 Phillips screwdriver to
remove the two screws retaining the
Canopy to the mounting plate.
Step 4:
Following the label on the mounting
plate, attach the supply power wires
to the power block on the mounting
plate. Refer to
Mounting Plate and Termination Board on page 4
.
Step 5:
Attach the power supply ground wire to the mounting plate.
Step 6:
Plug in the input DMX/RDM connector (and thru DMX/RDM connector if
used) to the appropriate location on the terminal board.
Step 7:
Attach the mounting plate to the junction box, ensuring the cables are
properly routed inside the box.
Data – (ORG)
Data + (W/ORG)
Cat5 (or equivalent) wire
termination to IDC connector
COM
BRN
GRN
W/GRN
BLU
W/BLU