Installing the canopy fixture, Dmx/rdm cable installation, If using belden 9729 for dmx/rdm input – ETC Desire D22 User Manual
Page 5
5
Installing the Canopy Fixture
The Canopy D22 Desire Series is installed on to a RACO 232 series 4 x 2-1/8 inch
deep double junction box. The fixture is supplied with a divider to separate the data
network from the line voltage inside the junction box.
DMX/RDM Cable Installation
Step 1:
Terminate DMX/RDM input from the control source to the junction box.
This connection could be Belden 9729 or Category 5.
If using Belden 9729 for DMX/RDM input:
a:
Reference the DMX Cable Preparation for
Screw Termination Setup Guide for
instructions to prepare and terminate
Belden 9729 for DMX input cable to the
screw terminal connector.
b:
Install the screw terminal connector with
wires terminated to the DMX/RDM Input
receptacle on the termination board.
C A U T I O N :
Separate the line voltage from the data side in the
junction box. Install the voltage barrier provided by
ETC.
Canopy
Installation hook
Junction box
(not provided)
Data/Voltage
divider
Mounting plate
assembly
From a DMX/RDM source
Data – (Black)
Data + (Red)
Belden 9729 (or equivalent) wire
termination to screw connector
4 to 8 = n/c
COM