beautypg.com

Enerpac HPT-Series User Manual

Page 4

background image

4

Table 1 - Specifi cations, HPN and HPT Series Hydraulic Hand Pumps

Model

Type

(speed)

Maximum Pressure Rating

psi [bar]

Oil Volume per Stroke

in

3

[cm

3

]

Usable Oil Capacity

in

3

[cm

3

]

Stage 1

Stage 2

Stage 1

Stage 2

HPT-1500

two-speed

200 [13.8]

21755 [1500]

0.687 [11.26]

0.151 [2.47]

155 [2540]

HPN-2000

two-speed

200 [13.8]

29000 [2000]

0.687 [11.26]

0.151 [2.47]

155 [2540]

6.1 Keep Oil Lines Clean

When coupler halves are disconnected, always install dust caps
or plugs. Use every precaution to guard the pump and oil lines
against entry of dirt and grit. Foreign matter in the system may
result in pump or valve failure. Such damage is not covered under
warranty.