Iv. control system specifications, Control system specifications, Iv. c – Elkhart Brass Scorpion 8394-04 User Manual
Page 10: Ontrol, Ystem, Pecifications

7
IV. C
ONTROL
S
YSTEM
S
PECIFICATIONS
Controller Specifications
• Power requirements
12VDC (9VDC to 14VDC)
• Control current
• Monitor motor run current for left-right
• Monitor motor run current for up-down
0.15 A
4.5 - 5 A* @ 200psi
4.5 - 5 A* @ 200psi
• Monitor motor stall current
27 A
• Current limit trip-out
6 A
• Nozzle motor run current
0.5 A
• Operating temperature range
-40
°F (-40°C) to 176°F (80°C)
Shock:
• 30 G's (55 Hz. @ .2 inch double amplitude)
Vibration:
•
15.5 G's (55 Hz. @ .05 inch double amplitude) continuous operation
Environmental:
• All enclosures have a NEMA 4 rating (must withstand a 1 inch stream of water (65GPM)
from a distance of ten feet for five minutes, with no water entering the enclosure).
Installation Instructions