Connections

Connection with Weigh Platform

The indicators mounted in an ABS enclosure ship with a 15 ft shielded load cell cable for
a connection to weigh platform’s load cell(s) or junction box.

1. Plug the cable’s 14-pin connector into the signal port on the rear panel of the

indicator. Wire the bare wires and shield to the weigh platform’s load cell(s) or
junction box using the color codes shown below:

RED: +Excitation
BLACK: - Excitation
GREEN: +Signal
YELLOW: - Signal


2. 2. If you do not wish to use the shielded load cell cable, you may use own, following

the pin assignments shown below:





Connection with Printer or Computer

The indicator comes standard with one full duplex RS-232 serial port, designed for
connection to either a PC or a serial printer. Below is the diagram:


Plug the serial printer, remote display or computer communication cable (not included)
directly into the D-SUB9 serial port connector.

Connection with Power Supply

The indicator comes with an external AC adapter. Simply plug the AC adapter into the its
DC Power Jack first, and then plug into a standard wall outlet.

1/8

+Excitation

3/10 -Excitation
5/12 +Signal
7/14 -Signal

2 Receive Data
3 Transmit

5 Signal Ground RS-232