beautypg.com

DIGIWEIGH DWP-L Series User Manual

Page 14

background image

13

NAME/CODE

DESCRIPTION

CODE/VALUE

A1
Baud Rate

Selects the baud rate for data transmission through the

serial port.

1200
2400 4800
9600
19200

A2
Data Bits and
Parity

Selects the number of data bits and parity of serial

transmission. "8n"=8 data bits with no

parity bit and one stop bit.

"7O"=7 data bits with odd parity bit and one stop bit.

"7E"=7 data bits with even parity bit and one stop bit.

"7n"=7 data bits with no parity bit and two stop bits

8n

7O

7E

7n

A3
Mode of
Serial
Transmission

Selects when data will be sent out of the serial port to a

printer or computer.

"C" = Continuous mode; send data continuously

"d" = Demand mode; send data when a PRINT

command is issued from the printer, computer, or

indicator.

C

d

A4
Display
Check

Actuates the function that illuminates all digit segments,

decimal points, and LCD annunciators in a test

sequence. Pressing the ZERO key to scroll down one

level begins the test sequence.

Press ZERO key

to begin

sequence

A5
Disable the
lb/kg Key

Allows the lb/kg key to be disabled so that an operator

cannot accidentally press the key and change the

display units.

"0" = Disable the lb/kg key "1" = Enable the lb/kg

key

0
1√