DIGIWEIGH DWP-102E User Manual
Page 5
- -
3
SECTION 3 OPERATIONS
3.1 Power on/off
Press ON/OFF Key to power on the Indicator and the indicator self-checks, then goes into
the weighing state.
3.2 Functions and parameters setting
When self-checking, press ZERO Key to enter parameter setting. Then display shows
“F1
CLK
”. Press TARE Key to move functions cycle. Press FUN Key to enter the desire
function or MOD Key to cancel or quite. See details on Section 4 Functions and
Parameter Sections.
When self-checking, press TARE Key to enter
“P8 CAL” calibration function.
When self-checking, press MOD Key to enter
“P13 UT” unit setting.
When self-checking, press FUN Key to stop self-checking and it goes into the work state.
When self-checking, press UNIT Key to enter unit conversion coefficient setting.
3.3 Zero the scale
Press ZERO Key to set the zero point from which all other weighing and counting is
measured. Usually this will only be necessary when the platform is empty. When the zero
point is obtained the ZERO indicator is ON.
The scale has an automatic re-zeroing function to account for minor drifting or
accumulation of material on the platform. However you may need to press ZERO Key to
re-zero the scale if small amounts of weight are shown when the platform is empty.
3.4 Tare the scale
When a container is applied it needs to tare off and obtains a net weight. Remove all
weights from the platform and make the platform empty. Make sure that the ZERO
indicator is on.
Place a container on the platform and the container’s weight will be
displayed. Press TARE K
ey to tare the scale. The container’s weight will be stored as a
tare value and the value will be subtracted from the display, leaving a zero value on the
display. The TARE indicator will be on to show the indicator is now under tare operation. A
product is placed in the container and it will show only the weight of the added product.