beautypg.com

DIGIWEIGH DWP-102E User Manual

Page 10

background image

- -

8

“P12 KB”: When “on”, keyboard is pressed with sound.
“P13 UT”: Unit setting. Lb, U1 or U2 is optional, which could be “ON” or “OFF” through

pressing the FUN Key and TARE Key. When U1/U2 is

“ON”, the conversion coefficient

can be set through pressing UNIT Key while self-checking. When U1/U2 is

“OFF”, it could

not be set unless entering the P13 UT menu and set it

“ON”.

“P14 Pn”: Press “FUN” to display “P1 ----” set the passwords and press “FUN”. It display
“P2 ----” and set passwords again to confirm. When successful ,it will show “Done”

SECTION 5 RS-232 OUTPUT

Specifications: RS-232 output of weighing data, 1200/2400/4800/9600/19200 bps,1 stop

bit, 8 data bits, No Parity.

Mode 1: Continue output

ST,GS 0.119,kg

ST for stable; US for unstable ; GS for gross weight; NT for net weight ; 0.119 for weighing

value; kg for unit (kg, lb); HEX 0d and HEX oa : HEX for hex; 0d for enter; 0a for next line.

Mode 2: Automatic output

Automatic output mode is same as continue output. The only difference is:

After weighing, when take away the goods display returns to zero, then transfers.

Data Format for normal weighing operations. Examples as follow:

Mode 3: Print. Setting Lab2

DATE 2000/02/11

TIME 21:26:56

NO. 001

TARE 0.000kg

NET 0.076kg

GROSS 0.076kg

DATE 2000/02/11

TIME 21:27:41

NO. 002

TARE 0.125kg

NET 0.035kg

GROSS 0.160kg

----------------

NO. 002

TOTAL 0.111kg