8
“P12 KB”: When “on”, keyboard is pressed with sound.
“P13 UT”: Unit setting. Lb, U1 or U2 is optional, which could be “ON” or “OFF” through
pressing the FUN Key and TARE Key. When U1/U2 is
“ON”, the conversion coefficient
can be set through pressing UNIT Key while self-checking. When U1/U2 is
“OFF”, it could
not be set unless entering the P13 UT menu and set it
“ON”.
“P14 Pn”: Press “FUN” to display “P1 ----” set the passwords and press “FUN”. It display
“P2 ----” and set passwords again to confirm. When successful ,it will show “Done”
SECTION 5 RS-232 OUTPUT
Specifications: RS-232 output of weighing data, 1200/2400/4800/9600/19200 bps,1 stop
bit, 8 data bits, No Parity.
Mode 1: Continue output
ST,GS 0.119,kg
ST for stable; US for unstable ; GS for gross weight; NT for net weight ; 0.119 for weighing
value; kg for unit (kg, lb); HEX 0d and HEX oa : HEX for hex; 0d for enter; 0a for next line.
Mode 2: Automatic output
Automatic output mode is same as continue output. The only difference is:
After weighing, when take away the goods display returns to zero, then transfers.
Data Format for normal weighing operations. Examples as follow:
Mode 3: Print. Setting Lab2
DATE 2000/02/11
TIME 21:26:56
NO. 001
TARE 0.000kg
NET 0.076kg
GROSS 0.076kg
DATE 2000/02/11
TIME 21:27:41
NO. 002
TARE 0.125kg
NET 0.035kg
GROSS 0.160kg
----------------
NO. 002
TOTAL 0.111kg