S
AFETY
LBB Series Oven Owner’s Manual
18
Version
18
2.6.1. Emergency Stop
When a risk of personal injury or damage to the LBB Series oven exists, turn OFF the oven by 
either the disconnect switch or removing/unplugging the cord. This shuts off all electrical power 
to the oven. 
2.7. Disconnecting Devices
2.7.1. Power Requirements
Despatch recommends the LBB Series Ovens have unobstructed access to a dedicated power 
source. 
Use a power stabilizer if voltage fluctuation is greater than ±10% 
nominal voltage fluctuation. 
2.7.2. Disconnecting Hard-Wired Units
LBB permanently-connected (hard-wired) ovens include models LBB1-69, LBB2-12, LBB2-18 
and LBB2-27. Permanently-connected and multi-phased equipment must employ a switch or 
circuit-breaker as means for disconnection. 
 
Notice
 
For permanently-connected equipment, installation instructions 
must specify a switch or circuit-breaker be included during the 
facility oven installation for complete isolation. 
 
 
 
The disconnecting device must be installed in close proximity to the equipment and within easy 
reach of the operator. The disconnecting device must be marked as the disconnecting device for 
the equipment. If the unit is equipped with an ON/OFF switch, mark the ON/OFF position 
clearly. 
 
 
Follow local codes and requirements for installing and using 
disconnect switches. 