Troubleshooting Error Messages and Alarms

Table 4 lists the more common error messages, possible problems and remedies.


Table 4. Error Messages and Next Steps.
Alarm Status

Possible Problem

Next Step

HI LIMIT LED ON

Problem with thermocouple

High Limit setpoint has
been exceeded.

Once the problem has corrected, press
RESET.

DEV HOLD LED flashing

Oven temperature has not
entered (or dropped out of) the
Auto Hold band and the soak
timer has stopped

Program a slower ramp rate or if oven
is not heating check heater circuit.

Top PV displays OPEN

Control thermocouple is
disconnected or broken

Repair or replace the thermocouple.

HLPV displays OPEN

High Limit thermocouple is
disconnected or broken

Repair or replace the thermocouple.

Danger!

Electrical panels contain high voltage. Turning the power switch
off on the oven does not de-energize the circuit board.
Disconnect and lock out the power supply before working on the
circuit board. Failure to lock out the power supply can result in
death or injury.