Temperature, Lac-7 series oven operating conditions – Despatch LAC2-12-7 User Manual
Page 12
![background image](/manuals/557518/12/background.png)
A
BOUT
T
HIS
M
ANUAL
LAC Series Oven
Owner’s Manual
12
Version 1
Copyright © 2012 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
1.5.4.
Temperature
LAC-7 Model Number
1-10
1-38 A
1-38 B
1-67
2-12
2-18
Time to Temperature
40 °C
– 100 °C
(approximate minutes
40 °C
– 200 °C
with no load)
40 °C
– 260 °C
8
25
40
9
32
60
6
22
36
6
20
34
6
19
31
4
17
29
Recovery Time - Door Open
100 °C
One Minute (approximate
200 °C
minutes with no load)
260 °C
1
3
7
1
6
14
1
4
8
1
3
5
1
6
9
1
4
8
Temperature Uniformity at
100 °C
3 F
§
200 °C
260 °C
± 1 °C
± 2 °C
± 2.5 °C
Operating Range with 20 °C Ambient
40 °C
– 260 °C
Control Stability
± 0.5 °C per 5 °C change in ambient
Repeatability
± 0.5° C
1.5.5.
LAC-7 Series Oven Operating Conditions
The LAC-7 Series oven is for indoor use. Table 1 provides the operating conditions.
Table 1. Operating/Environmental Conditions (For indoor use).
Item
Description
Operating Temperature
**
18°C to 40°C (64.4°F to 104°F)
Relative Humidity
70% non
‐condensing
Maximum Altitude
2,000 meters (6,600 feet)
§
Figures are based on actual tests in an empty oven. Uniformity can vary slightly depending on unit and
operating conditions.
**