beautypg.com

Comelit MT CT 01 User Manual

Page 17

background image

GROUP S.P.A.

MT CT 01

16

Relay controls
With the microtelephone lifted, it is possible to activate the following relay outputs:

Table 4: Description of the relays present on card 2909

Adjustment of external unit volume
The sound of the entry phone interface has been designed in full-duplex mode, according to which the person
speaking can also listen to their interlocutor. It has volumes preset by Comelit , and once a conversation with the
external unit is set up, it is in nay case possible to adjust them directly from the telephone by using buttons 1 – 7 – 3
– 9, according to the method shown in the figure below. 17 adjustment levels are possible, and each time the button
is pressed, the volume is changed by 1 level. It is necessary to digit number 2 to store the volume levels reached.

TERMINAL

DESCRIPTION

POWER

COMTEL BCA

NOTES

N1 – C1

“Door Opener”

Relay Max

#

The output can be configured

Control

7 A

as bistable or as monostable.

80Vdc –

This output can be activated

50Vrms

remotely remote on a call from

the telephone line.

N2 – C2

“Stair Lights”

Relay Max

*

The output can be configured as:

control

1A -

- Bistable or as monostable.

24Vdc –

- Internal Lighting-up use or generic use.

120Vrms

If configured as Internal Lighting-up,

the output cannot be activated

remotely with the Relay Remote

Check service.

N3 – C3

“Gate opener”

Relay Max

5

The output can be configured as

1A -

bistable or as monostable.

24Vdc –

This output can be activated

120Vrms

remotely remote on a call from the

telephone line.

#

9

8

7

4

5

6

1

2

3

To increase the
volume in the
External unit –
Extension branch
direction

To increase the volume
in the
Extension branch –
External unit direction

Storage of the
volumes reached.

To decrease the volume
in the
Extension branch –
External unit

To decrease the volume
in the External unit –
Extension branch
direction