Table 2: Switchboard terminals and associated expansion cards

TERMINAL

FUNCTION

EXPANSION

EARTH

Earth terminal

L1 - L1

Terminals of line 1

L2 - L2

Terminals of line 2

2908

5V

5V power supply terminal for telephone OP

RX

RX terminal for OP

TX

TX terminal for OP

T1

Terminals of branch 1.

T2

Terminals of branch 2.

T3

Terminals of branch 3.

T4

Terminals of branch 4.

T5

Terminals of branch 5.

2907

T6

Terminals of branch 6.

2907

T7

Terminals of branch 7.

2907

T8

Terminals of branch 8.

2907

2

Sound towards external unit entry phone microphone

2909

3

Sound towards external unit entry phone loudspeaker

2909

4

Entry phone system ground

2909

S1

Entry phone 1 call input signal

2909

S2

Entry phone 2 call input signal

2909

S3

Entry phone 3 call input signal

2909

S4

Entry phone 4 call input signal

2909

+24

Output voltage +24Vdc ( max 30mA )

2909

GND

Ground

AL

Alarm input for remote SOS line service

2913

N1

Relay contact 10A ( can be activated with DTMF digit # )

2909

C1

Relay contact 10A ( can be activated with DTMF digit # )

2909

N2

Relay contact 1A ( can be activated with DTMF digit * )

2909

C2

Relay contact 1A ( can be activated with DTMF digit * )

2909

N3

Relay contact 1A ( can be activated with DTMF digit 5 )

2909

C3

Relay contact 1A ( can be activated with DTMF digit 5 )

2909

230VAC

Mains power supply 230V (on the terminal external poles)

BAT 12V

Input for emergency battery (max 80mA)

Jack Connector

Input for external music